It IS VERY IMPORtANt tO FOLLOW thE SAFEtY INStRUCtIONS.
• Do not breathe the ozone directly above the
unit.
• Make sure no one iS preSent in the room
during the treatment for 1 hour (men, women, chil-
dren, and also pets). Plants and fish may remain.
• Close doors, windows, and turn off the ventila-
tion system.
Active oxygen is made up of 3 molecules
of oxygen (O
), also known as ozone.
3
the ozone generator recreates the phe-
nomenon of lightning during a storm.
It destroys VOCs, bad odours, dust mites
and spores.
Ozone is better at killing certain micro-or-
ganisms than chlorine. Ozone created
electrically returns to its initial form of oxygen (O
in a few hours.
When this feature is inactive, your unit is
emitting 0 ppm of ozone.
toneS
the tONES are activated as soon as you press on a button, and as soon as ozone is emitted. to
activate the tONES, press the ON button. to deactivate them, press the OFF button.
high SenSitivity
this mode is recommended for people who are very sensitive to air quality. the hIGh SENSItIVI-
Ty mode should be activated in an indoor environment with little pollution when your air manager
is in ACtIV MODE. the unit adapts its operation by taking the low level of pollution into account,
and can therefore detect smaller peaks in pollution. to activate the hIGh SENSItIVItY mode, press the ON
button. to deactivate it, press the OFF button.
reSet
To RESET the settings on your unit, press the ON button. All of the custom and saved data will be
erased.
demo
DEMO mode is a general presentation tool for the air manager (used mainly in retail outlets where
this model is sold). to activate DEMO mode, press the ON button. to exit this mode, press on the
cross in the top left corner of your screen.
to hide this mode, hold down the OFF button.
verSion
Get technical information about your air manager (model and software). this information may be
requested when you contact your dealer.
22 - EOLIS Air Manager 600 600 S 1200 1200 S
WhEN mode 2 IS ACtIVAtED,
• As soon as you press StArt, a countdown ap-
pears telling you that you have 30 sec to leave the
room:
As you leave, close the door behind you.
1 - the unit emits ozone for 15 minutes at a low
rate.
2 - For the following 45 minutes, the unit is no
longer emitting ozone, and works at high speed to
absorb the ozone in the air.
3 - After at least 1 hour, the unit begins operating
normally with the preset settings.
)
You can return to the room.