POMPE MCB+
1.
SYMBOLS MEANINGS USED HEREIN
DANGER
Risk of electrocution.
DANGER
Risk of personal injury.
ATTENTION
Risk of pump and system deterioration.
2.
GENERAL SAFETY INSTRUCTIONS
The instructions listed below are purely indicative and in no way limited. The pump must always
be handled with the most care.
▪ The pump was designed for use in a closed circuit, in clean water at a temperature less than 35° C.
▪ Do not modify the pump in any way; the guarantee will automatically be invalidated in the event of a pump
modification.
▪ For all repair work, only use spare parts supplied by the manufacturer; the latter will not be held liable in the event
of damage caused by the use of non original spare parts or parts which have been modified without prior approval of
the manufacturer.
▪ The safety and correct operation of the pump are guaranteed only if all the installation and commissioning
instructions have been followed.
▪ The pump must be installed in compliance with the applicable standards in force in the country of installation and
use, especially HD 384.7.702; we recommend you contact a professional for the pump installation.
▪ Cut off the electricity supply to the pump prior to any intervention.
▪ The limits specified in the technical data table must never be exceeded under any circumstances.
▪ In the event of a malfunction or failure, please contact your nearest manufacturer's representative or the
manufacturer's Technical Support Service.
▪ Hot surface in the area around the motor
3.
INSTALLATION AND STARTING UP
▪ Never operate the pump without the prefilter.
▪ Never operate the pump without any water.
▪ Your pump is fitted with a prefilter basket designed to collect any large impurities which could damage the turbine.
▪ To ensure the correct operation of the pump:
- Always operate the pump with the prefilter in place,
- The pump must be installed horizontally and secured in place.
▪ Its performance is optimized if the pump is positioned below the swimming pool's water level.
▪ If the pump has to be installed above the swimming pool's water level, the height must not exceed 1,5 m and the
length of the suction pipe will have to be as short as possible in order to avoid significant suction times and pressure
losses (diagram no. 1).
▪ For the correct air circulation and to ensure effective cooling,
the fan grid must be located more than 30cm from a wall.