The configuration Menu is accessed by pressing the DHW buttons together for 10 sec-
onds. 7 parameters indicated by the letter "b" are available: which are not modifiable from
Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to modify the value of a parameter: the change will be au-
tomatically saved.
Contents Description
Range
0=Natural Gas
b01
Gas type selection
1=LPG
1=Bithermal instantaneous
2=Monothermal instantaneous
b02
Boiler type selection
3=Heating only (3-way valve)
4=Heating only (circulating
pump)
0=Sealed Chamber combustion
control
(without fume pressure switch)
1=Open Chamber
(with fume thermostat)
Combustion chamber type
b03
2=Sealed Chamber (with fume
selection
pressure switch)
3=Sealed Chamber combustion
control
(with fume thermostat on
recuperator)
0=Flat
Primary Exchanger type
selection
1=Omega
(b03=0)
2=--
No effect on adjustment
--
(b03=1)
b04
No effect on adjustment
--
(b03=2)
0=Flat
Primary Exchanger type
selection
1=Omega
(b03=3)
2=--
0=External gas valve
Relay card LC32
1=System filling solenoid valve
operation selection (b02=1)
2=Solar 3-way valve
No effect on adjustment
--
b05
(b02=2)
No effect on adjustment
--
(b02=3)
No effect on adjustment
--
(b02=4)
0=50Hz
b06
Mains Voltage Frequency
1=60Hz
Comfort burner on time
0-20 seconds
(b02=1)
No effect on adjustment
--
(b02=2)
b07
No effect on adjustment
--
(b02=3)
No effect on adjustment
--
(b02=4)
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting
occurs automatically after 2 minutes.
Service menu
The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 sub-
menus are available: press the Heating buttons to select, in increasing or decreasing or-
der, "tS", "In", "Hi" or "rE". tS" means Transparent Parameters Menu, "In" Information
Menu, "Hi" History Menu: after selecting the submenu, press the Reset button again to
access it; "rE" means History Menu Reset: see description.
"tS" - Transparent Parameters Menu
16 parameters indicated by the letter "P" are available: which are also modifiable from
Remote Timer Control.
Default
CIPREA D 24 - 32 A
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
0=Natural Gas
0=Natural Gas
der. Press the DHW buttons to modify the value of a parameter: the change will be au-
tomatically saved.
1=Bithermal
1=Bithermal
instantaneous
instantaneous
0=Sealed Chamber
1=Open Chamber
with
(with TF)
combustion control
0=Flat
0=Flat
0
0
0=Flat
0=External gas
0=External gas
valve
valve
0
0
0
0=50Hz
0=50Hz
5 seconds
5 seconds
5
5
5
Notes:
1.
2.
3.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 sec-
onds to exit the card Service Menu, or exiting occurs automatically after 15 minutes.
cod. 3541A341 - 05/2011 (Rev. 00)
Contents Description
P01
Ignition ramp Offset
P02
Heating ramp
P03
Heating standby time
P04
Heating Post-Circulation
P05
Max. heating temperature
P06
Max. heating power
Burner shutdown in hot water production
(b02=1)
P07
Burner shutdown in hot water production
(b02=2)
Hot water tank hysteresis (b02=3)
Hot water tank hysteresis (b02=4)
DHW standby time (b02=1)
DHW standby time (b02=2)
P08
DHW standby time (b02=3)
DHW standby time (b02=4)
DHW user max. set point (b02=1)
DHW user max. set point (b02=2)
P09
DHW user max. set point (b02=3)
DHW user max. set point (b02=4)
Anti-inertia function temperature (b02=1)
No effect on adjustment (b02=2)
Delivery temperature in hot water produc-
P10
tion (b02=3)
Delivery temperature in hot water produc-
tion (b02=4)
Anti-inertia function Post-Circulation
(b02=1)
DHW Post-Circulation (b02=2)
P11
DHW Post-Circulation (b02=3)
DHW Post-Circulation (b02=4)
P12
DHW max. power
P13
Absolute min. power
P14
Post-Ventilation
CO2 limit Offset (b03=0)
No effect on adjustment (b03=1)
P15
No effect on adjustment (b03=2)
CO2 limit Offset (b03=3)
P16
Exchanger protection activation
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
The Maximum Heating Power parameter can be modified also in Test Mode.
Range
Default
CIPREA D 24 - 32 A
0-40
10
10
1-20°C/minute
5°C/minute
5°C/minute
0-10 minutes
2 minutes
2 minutes
0-20 minutes
6 minutes
6 minutes
31-85°C
85°C
85°C
0-100%
100%
100%
0=Fixed
1=Linked to set point
2=Solar (5)
0=Fixed
1=Linked to set point
3=Solar (10)
4=Solar (20)
0=Fixed
1=Linked to set point
2=Solar (5)
0=Fixed
3=Solar (10)
4=Solar (20)
0-4°C
2°C
0-4°C
2°C
0-60 seconds
30 seconds
30 seconds
0-60 seconds
60 seconds
0-60 seconds
30 seconds
0-60 seconds
30 seconds
50-65°C
50°C
50°C
50-65°C
55°C
50-65°C
65°C
50-65°C
65°C
70-85°C
70°C
70°C
--
0
70-85°C
80°C
70-85°C
80°C
0-5 Seconds
0 seconds
0 seconds
0-60 Seconds
30 seconds
0-60 Seconds
30 seconds
0-60 Seconds
30 seconds
0-100%
100%
100%
0-100%
0%
0%
0=Default
0=Default
0=Default
1=50 seconds
0 (Minimum)
20
20
30 (Maximum)
--
20
--
20
0 (Minimum)
20
30 (Maximum)
0=No F43
10°C/second
10°C/second
1-15=1-15°C/second