During use, always hold the machine with both hands and maintain a
safe standing position. Start up and run down the machine in the mixing
container only. Pay attention to the reaction moment of the machine.
For further safety instructions, please refer to the enclosure.
Electrical Connection
Before starting the machine, please check the correspondence between voltage
and frequency against the data mentioned on the identification plate. Voltage
differences of + 6 % and – 10 % are allowed.
The Stirrer EHR 20 / 2.5 S is made in protection class II. Only use extension
cables with a sufficient cross section. A cross section which is too small could
cause a considerable drop in performance and an overheating of machine and
cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
Tool Change
Attention!
Before any work on the tool, disconnect the plug from the mains!
When inserting the tool, you could catch your hands. For this reason,
always wear protective gloves for changing the tool.
The work spindle of the machine has an M 14 - internal thread. Keep threads and
front surface clean.
Please hold up with a jaw wrench 22 to remove the stirring rod.
Tool Protection
Wrong handling can cause damages on the tool. Therefore, the following
instructions should be observed:
Only use stirring rods which have a M 14 – external thread
(diameter 140 mm max.) and are recommended by the producer.
Do not allow blocking of the tool.
Only use original accessories made by EIBENSTOCK.
Cross section in sq. mm
1.5
20 m
50 m
2.5
40 m
80 m
12

Publicité