Assembly

The seat height must be determined and adjusted by a
professional.
• Both of the user's feet must be on the floor while
seated.
• Take a regular chair on which the user can sit
comfortably.
• Have the user sit on the chair.
• Measure the height of the seat of the chair.
• From the adjustable measurements of the folding
shower seat ( 465, 490, 515 or 540 mm), select the
measurement which is closest to the measurement
determined and transfer this measurement from the
floor of the shower basin to the wall.
• Cut a window in the drilling template around the cen-
ter line
• Lay the drilling template in position and transfer the 8
drill holes to the wall. If possible, use the gaps between
tiles for drilling to avoid damaging the tiles.
• Drill the holes and insert the anchors.

Height adjustment of the feet

To adjust the height of the footrests, first loosen the fixa-
tion clamp (pic. 1).
1
Then the footrests can be adjusted to one of 4 heights
(pic. 2), for seat heights of 465, 490, 515 and 540 mm.

Compensating for uneven surfaces

3
4
Drive Medical GmbH & Co. KG | As per: 08.06.2020 | Errors and alterations excepted
2
To compensate for any un-
evenness in the shower,
one foot is equipped with
fine adjustment (pic. 3).
Adjust the foot on the floor
by screwing it in or out and
then lock the set screw
with the two locking nuts
as shown (pic. 4).

Folding up and down

To fold the folding shower seat up or down when not in
use, always grip the seat (pic. 5) only, never as shown in
pic. 6 - Risk of pinching!"
5

Cleaning | Maintenance

• Clean regularly with a moist cloth!
• Do not use any aggressive cleaning agents!
• Do not use abrasive cleaners!
• Do not use any high-dose chlorine and vinegar-based
cleaners!
• To disinfect, a spray disinfectant can be used such as
Descosept AF or Bacillol AF.
• Check the screws regularly and tighten, if necessary.
• In the event of defects, contact your specialist dealer
from whom you purchased this product.

Technical data

Product
Article number
HMV (medical aids register)
no.
Overall width
Overall height
Overall depth
Seat width x Seat depth
Seat height
wall clearance /
seat depth to the wall
Total weight
Load max.
Material frame
Material seat section
EN
6
DKS 130
550700100
04.40.03.0029
48 cm
61 cm
50 cm
41 cm x 41 cm
46,5 - 54 cm
32 cm / 49 cm
4,1 kg
130 kg
Welded steel tubing,
powder-coated
PP (polypropylene) /
PU (polyurethane)
9