BEFORE USING THE POWER SUPPLY UNIT
Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.
Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
DANGER
Never use this product in locations where flammable gas or ignitable substances are present. There are risks of igniting these substances and
exploding by an arcing.
WARNING
Do not touch this product or its internal components while circuit is live, or shortly after shut down. There may be high voltage or high
temperature present and you may receive an electric shock or burn.
When this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation.
Do not make unauthorized changes to this product, otherwise you may receive an electric shock and void your warranty.
Do not drop or insert anything into this product. It might cause a failure, fire and electric shock.
Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. It might lead to fire and electric
shock. In such cases, please contact us. Do not attempt repair by oneself, as it is dangerous for the user.
Do not operate these products in the presence of condensation. It might lead fire and electric shock.
CAUTION
This power supply is designed and manufactured for use within an end product such that it is accessible to SERVICE ENGINEERS only.
Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on.
Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, otherwise the
product will be damaged.
Do not use this product in environment with a strong electromagnetic field, corrosive gas or conductive substances.
For applications, which require very high reliability (Nuclear related equipment, medical equipment, traffic control equipment, etc.), it is
necessary to provide a fail-safe mechanism in the end equipment.
Do not inject abnormal voltages into the output of this product. The injection of reverse voltage or over voltage exceeding nominal output
voltage into the output terminal might cause damage to internal components.
Never operate the product under over current or short-circuit conditions for more than 30 seconds, or outside its specified Input Voltage Range.
Insulation failure, smoking, burning or other damage may occur.
PCB stress such as bending, twisting etc. could cause damage. Therefore, please handle with care.
When handling this product, hold the board edge and take care not to touch the component side. When installing this product in apparatus or
equipment, mount it on spacers.
This power supply has possibility that hazardous voltage may occur in output terminal depending on failure mode. The output of these products
must be protected in the end use equipment to maintain SELV.
This product has used Power Thermistor to protect the circuit from Inrush Current. Frequent repetition of input might cause damage to internal
components because of generating surge current.
Breaking of internal fuse is considered internal failure. In such cases, please contact us.
The information in this document is subject to change without prior notice. Please refer to the latest version of the data sheet, etc., for the most
up-to date specifications of the product.
Double pole / neutral fusing.
No part of this document may be copied or reproduced in any form without prior written consent of TDK-Lambda.
MARKING
Note: CE
CE marking, when applied to the CUS200M series products, indicates compliance with the Low Voltage Directive
EN60950-1.
CUS200M
Instruction Manual
- 1 -
TDK-Lambda
CUS200M
Instruction Manual
(2006/95/EC) in that it complies with
DWG No.: CA811-04-01A
APPD
CHK
DWG