PLACING THE MACHINE IN SERVICE
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
1
2
Model
Belt size
mm
V.402F
10 x 330
Model
Free speed
rpm
V.402F
16000
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT V.402F – FACOM PNEUMATIC BELT SANDER
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN ISO 11148-8: 2011
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-3:2009
LUBRIFICATION
3
4
V.402A1
V.402A2
Pressure dB(A)
86,1
Air
consumption
l/min
110
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
Noise level
Power dB(A)
k*
k*
3
97,07
Working
Weight
pressure
bar
6,2
EMERGENCY
GATE VALVE
5
A
Pressure dB(C)
k*
3
87
3
Dimensions
kg
mm
0,80
283 x 83
F
ACOM QUALITY MANAGER
B
Vibrations level
m/s
2
k**
< 2,5
0,63
20.01.2010