Receiving automatic SMS Alarm messages
In the event of an alarm, SMS alarm messages will be sent to every registered phone.
SMS received
Example 1:
SMS:OK
SIG:100%
EN:OK
EA:OK
Z1:OK
Z2:OK
Z3:99A! 2.8kV!
Example 2:
SMS:OK
SIG:100%
EN:33A 2.6kV!
EA:3.0kV!
Z1:15A 2.2kV!
Z2:18A 1.9kV!
Example 3:
SMS: MAINS FAILURE
LOW BATTERY!
SIG: 57%
EN: MAINS POWER
FAILURE
Important: When the power fails, the SMS Energizer Controller will switch to the
back-up ba ery pack. It is recommended that you replace the ba eries in the
ba ery pack a er any signifi cant main power supply failure, or if there are no such
failures, every 1-2 years to ensure power is available when needed.
48
Gallagher SMS Energizer Controller Manual
Explana on of informa on
received
Example 1 shows zones 1 to 3
are connected and working.
Zone 1 and 2 have no alarms
Zone 3 has both voltage and
current alarms.
In Example 2, the Energizer,
earth, zone 1 and zone 2 are in
voltage alarm.
In Example 3, the Energizer
and Energizer Controller mains
is off . The SMS Energizer
Controller ba eries are low.