Module de commutation/variation radio simple
Switch-off warning
Priority, lock-out protection
Activate lock-out protection
switching state
Deactivate lock-out protection
switching state
Priority, restraint
Activate forced operation swit-
ching state
Deactivate forced operation
switching state
Priority, wind alarm
Activate wind alarm switching
state
32582722
10864994
On, Off
Basic setting: Off
0...4
Basic setting: 1
On, Off
Basic setting: Off
On, Off
Basic setting: Off
0...4
Basic setting: 2
On, Off
Basic setting: On
On, Off
Basic setting: Off
0...4
Basic setting: 3
On, Off
Basic setting: Off
27.04.2017
If the switch-off warning is ac-
tive, then, during switch-off,
the systems dims to minimum
brightness within 30 seconds
and only then switches off. If
the parameter "Dim down
ramp" is configured as longer
than 30 s, then the length of
the dim down ramp is applied.
If, during the dim down opera-
tion, another command is gi-
ven, e.g. switch on or scene
recall, then the switch-off war-
ning stops and the command
is executed. A switch-off com-
mand restarts the time for the
switch-off warning.
Note: The set time apply to
operation using radio transmit-
ters. The device is switched
immediately when the Prog
button is pressed.
Specifies the priority for recal-
ling and removing a scene of
type Lock-out protection for
the channel.
Note: 1 is the highest priority
and 4 the lowest. 0 means no
priority.
Defines the behaviour of the
output on activating the lock-
out protection.
Defines the behaviour of the
output on deactivating the
lock-out protection. Only vi-
sible when the priority for the
lock-out protection is 0.
Specifies the priority for recal-
ling and removing a scene of
type Restraint for the channel.
Defines the behaviour of the
output on activating the forced
operation.
Defines the behaviour of the
output on deactivating the for-
ced operation. Only visible
when the priority for the forced
operation is 0.
Specifies the priority for recal-
ling and removing a scene of
type Wind alarm for the chan-
nel.
Defines the behaviour of the
output on activating the wind
alarm.
13/15