R – Machine equipped with ramp table
Named (I) : machine equipped with cut on the left hand side.
NOTE: The specifications could be changed without prior notice.

14. ELECTRICAL DIAGRAMS:

See page 27.
15. TECHNICAL SERVICE: VOLTAGE CHANGING
1. Unplug the machine.
To change from 400V to 230V or from 230V to 400V,
two operations must be made after opening the low
tension box (21)
Follow the wiring diagram in page 27 and the drawing
indicated underneath to change voltage.
- Connector nº 1: Change depending on the desired
voltage.
- Connector nº 2: Change depending on the desired
voltage.
ATTENTION: Both connections must be made on the
same voltage.
Close the covers of the low-tension box (21).
The new voltage connection must be written at the rating plate.
16. BLADE TURNS ON THE OPPOSITE DIRECTION, SOLUTION
1.- Unplug the machine.
2.- Open the low tension box (21).
3.- The network cables (13) colour blue, black and brown which go on connector at box (21) to numbers 1, 3 and 5
must be interchanged two from the three. See the wiring diagram.
4.- Place the cover of the box (21).

17. FUSE CHANGE

1.- Turn off the machine
2.- Open the box of the plate 24V (21)
For fuse F2:
- Replace the fuse for a new one, depending on the reference 5X20, 250V, 2A.
- Reinstall the cover of the box (21)
For fuses F3:
- Replace the fuse for a new one, depending on the reference 5X20, 250V, 0,5A.
- Reinstall the cover of the box (21)
See electrical diagram
STL 350
STL 390
300
360
2.500
2.910
155
190
170
205
155
190
160
195
STL 430
STL 480
400
450
3.155
3.500
205
235
220
250
205
235
210
240
230
400
0
0
24
1
2

Publicité

Table des Matières
loading

Table des Matières