Battery parameters
Switch-on voltage
Switch-off current
Switch-off voltage
Absorption time
Page 76
www.busse-yachtshop.de | info@busse-yachtshop.de
Function
The EFOY fuel cell switches on at the set voltage
and charges the battery.
Setting too high a value for the switch-on
voltage results in frequent starting of the EFOY
fuel cell. Setting too low a value for the switch-
on voltage results in damage to the battery. The
default value is 12.3 V, which corresponds to
approx. 50% of the battery charge condition.
The EFOY fuel cell switches off if the current
drops below the set switch-off current.
If you want the battery voltage to serve as the
only switch-off parameter, please set the
maximum value, as the current is always below
this value in EFOY fuel cells.
If the battery voltage reaches the set level, the
EFOY fuel cell switches off, provided that the
value set for the "Switch-off current" parameter
has also been reached.
Please note your battery's end-of-charging
voltage. Please note the charging
recommendations provided by the battery
manufacturer.
This function serves as an additional switch-off
criterion for EFOY fuel cells if the switch-off
current level is not reached within the set time
period.
This period is set by default to 3 hours, but can
be changed to any value between 0 and 5 hours.