ADDENDUM «010528» for the following version-9910 manuals:
1. An anti-bouncing control for the probe signal.
The probe signal must stay stable, inactive, for at least 100 milliseconds in order to accept another probe
pulse.
2. A probe operation error has been corrected.
When the probe is active (it has touched a point), if a value was preset, this preset would be applied to the
exact point where the probe was activated even if the axis was at another position at the time of the
preset.
3. The resolution parameter for a rotary axis PAR 01 may have any value between 0.0001 and 1.0000.
This allows reading the position of rotary axes having a mechanical reduction or multiplication device
providing an unusual number of pulses per revolution (360º). For example: 1200, 1250, 3000, 3200, 9600,
etc.
In general, any resolution value (360º / Nr of pulses) that may be given with 4 decimals.
4. When pressing the [1] key, the display of rotary axes toggles between degrees and degrees-minutes-
seconds .
5. Improved bolt-hole drilling cycle.
Now, to access the cycle, it is no longer necessary to press [ENTER] after the bolt-hole selecting key..
While executing, press ENTER to go to the next hole. If pressed in the last hole, it will roll on to the first hole
so as for tapping the holes just drilled, etc. Press [CLEAR] to exit the cycle.
The data are stored in such a way that the next time the bolt-hole cycle is accessed, it will offer by default
the data of the cycle previously executed. The data is lost when the unit is turned off because they are in
RAM memory.
6. A new parameter is now available to limit the access to certain characteristics of the dro.
PAR 65
Bit 1 ->
Allow fine/coarse resolution key
Bit 2 ->
Allow [HOLD] key
Bit 3 ->
Allow bolt-hole key
Bit 4 ->
Allow [stand-by] key. S1-S6 outputs
Bit 5 ->
Allow direct access to PAR05
Bit 6 ->
Allow tool radius compensation keys
Bit 7->
Allow selecting an electrode diameter
Bit 8->
Allow presetting the electrode length
By default, they will all be set to 1, thus allowing all the options. The machine manufacturer may limit the
user's access according to his criteria.
7. A new feature to control maximums and minimums is now available.
When the DRO is set as NV10 or NV11, the [7] key will be used to switch between Min, Max and Normal
display.
Min. mode:
It displays the minimum position reached by the axis.
NV-xx
code: 14460000
NV-xxx-M code: 14460001
NV-xxx-E
code: 14460003