Automatic Cellar Dehumidification Aero_aH100
Successful dehumidification –
Button 1 / Blinking LED 2:
In the case that the room humidity
is reduced by at least 0.2 g/m3, in
comparison to the reference value,
the Aero_aH100 signals successful
dehumidification by LED 2 blinking.
A reference value of 9 g/m3 is set
on-site. A new reference value can
be set at any time by pushing
button 1 during ongoing operation.
Saving of the new reference value is
confirmed by the LED 2 blinking
briefly.
Manual ventilation – Button 2:
The Aero_ah100 switches the fan
on and off automatically and in a
manner optimised to demand.
When off, the fan can be switched
on manually with button 2 and
manual ventilation therefore takes
place. Manual operation is ended
by again pressing button 2 or
automatically after approximately
20 minutes.
Optionally, manual operation can
take place with an external button,
see wiring diagram in Chapter 14.
The fan cannot be switched off
manually using the button when in
the automatic operating mode.
Manual ventilation is also possible
during frost protection and
protection against insufficient
humidity.
Manual ventilation – external
button/switch:
Optionally to button 2, manual
operation can take place with an
external button or switch, see
wiring diagram in Chapter 14.
To achieve this, an automatic
button/switch recognition via the
duration of the first activation after
power is supplied. A switch is
recognised when the switching
contact is closed for more than
10 seconds.
Manual ventilation with an external
button is equivalent to using
button 2.
If an external switch is connected,
manual ventilation is switched on
or off in accordance with the switch
setting. An automatic switch-off of
the manual operating mode does
not exist in this case.
Frost protection:
To prevent the room from cooling
down, the Aero_aH100 has a frost
protection function. This means
that the fan automatically switches
off at inside room temperatures of
less than 5 °C.
Protection against insufficient
humidity:
For reasons of health protection
and energy efficiency, the
Aero_aH100 offers a protection
against insufficient humidity
function. This protective function
ensures the switching off of the fan
if a relative humidity of less than 30
% is reached.