The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
5.3 Outputs
Output is via 8 IEC sockets on the rearpanel.
Connect your loads via the output-sockets. The maximum load per channel is 6 A. Please note that the
maximum current of 10 A must never be exceeded.

6. OPERATION

Pull the two aluminium tubes out. Switch the LEDs on using the LED On/Off-switch. Adjust the desired
brightness via the dimmer and turn the tubes into the desired position.
Press the power switch on the right in order to switch the output-sockets on.

7. CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
The examination intervals for mobile electrical devices (German BGV A2) must be kept.
The operator has to make sure that the electrical devices are examined by an electrician before taking into
operation for the first time and after changes before taking into operation another time.
Electrical devices must only be taken into operation in a perfect condition and must be kept this way.
For keeping the perfect condition, electrical devices must repeatedly be approved in accordance with the
instructions given in the electro-technical guidelines.
A qualified electrician is responsible for the correct examinations.
Mobile electrical devices, extension cords with plugs, power cables with plugs and mobile cables with plugs
and permanent installation must be approved by an expert every three months.
International
L
N
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
13/24