Technical data
Re-chargeable vacuum cleaner
Rated voltage
Vacuum power
Protection class
Battery charging time : 4 hrs.
Dust container capacity : 0.5 L
Power adaptor
Model
Rated Input
Rated output
Protection class
Troubleshooting
If there are any problems during operation, please refer to the following table. If problems cannot
be solved as indicated under Solution, please contact your manufacturer.
Problem
Product does not work
Product cannot absorb
dust or loose suction
power
Rolling brush does not
work
Floor nozzle difficult to
move or get jammed
IM_KVR296_160105_V06_HR.indb 23
: 29.6 V
: Max. 150 W
: III
: ZD36W360100EU
: 100 - 240 V ~
50/60 Hz 1A
: DC 36 V 1A
: II
Possible causes
• Interrupted power supply
• Battery is empty
• Filters are blocked with dirt
• Dust container full, exceed
MAX marking
• Brush is blocked with threads
and hairs
• Wheels are blocked with
threads and hair
English
Solution
• Check the power supply
• Re-charge battery
• Clean and wash the filters
• Empty dust container
• Cut and remove the threads
and hairs from the brush
• Remove them carefully by
using a flat screwdriver