Management; Storage; Transport; Weight And Dimensions - Kramp D-DW Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
Electrical data
P1 Rated absorbed power [W]
Mains voltage [V]
Mains frequency [Hz]
Current [A]
Capacitor [µF]
Capacitor [Vc]
Hydraulic data
Max. flow rate [l/min]
Max. head [m]
Max. head [bar]
Max. immersion depth [m]
Min. AUT starting height [mm]
Min/max. stopping height [mm]
Residual water height [mm]
Range of use
Length of power cable [m]
Type of cable
Grade of motor protection
Insulation class
Liquid temperature range [°C]
according to EN 60335-2-41 for domestic use
Max. particle dimension [mm]
Max. ambient temperature [°C]
Weight
DNM GAS
Net/Gross weight approx. [kg]
The pump which does not stand on a base cannot support the weight of the pipes, which must be
supported in some other way.

4. MANAGEMENT

4.1 Storage

All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.

4.2 Transport

Avoid subjecting the products to needless impacts and collisions.

4.3 Weight and dimensions

The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.

5. WARNINGS

The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use
the handle provided.
The pump must never be allowed to run when dry.
On the body there is a venting hole to avoid phenomena of cavitation when starting the pump.
for a small amount of water to come out of the pump during operation. (Fig.1).
The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the
case of pure water, if the pump were to have any leaks.

6. INSTALLATION

Screw on the elbow with hosetail fitting provided in the packaging. For the dirty water version only the fitting for 30 mm
pipes; if you want to use a pipe with a larger diameter, change the elbow coupling. Use a pipe tightening clamp to secure
the pipe to the fitting.
It is advisable to use pipes having an internal diameter of 30 mm to avoid the decrease of pump performance and the
possibility of blocking.
If the bottom of the trap where the pump is to be placed is particularly dirty, a raised support should be provided so as
to avoid blocking of the suction grid (Fig.2)
Totally immerse the pump in the water.
Ensure that the minimum dimensions of the trap in which it is housed are as follows:
Min. base dimensions (mm) 460x460 / Min. height (mm) 400
Pay attention to ensure that the float is free to move, leave at least 5 cm from the wall of the trap.
ENGLISH
Model
Table 3
2
Draining dirty water
300
330
220-240 AC
50
1.5
8
450
130
5.5
0.55
7
260
100/150
10
10
H05 RNF
IP X8
B
0 °C / +35 °C
Ø 30
+40°C
1'' 1/4 F
4.2/5.15
It is therefore normal
400
440
1.6
140
7
0.7
4.65 / 5.6