Troubleshooting Bac-20P; Maintenance; Cleaning Internal Compressor Parts; Warranty Disclaimer - AIR SYSTEMS INTERNATIONAL BAC-10 Manuel D'utilisation

Masquer les pouces Voir aussi pour BAC-10:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROBLEM
Motor will not start Insufficient pressure
Motor icing (exterior) Very high humidity

MAINTENANCE

Note: Most problems can be prevented by keeping filters clean. Dirty filters decrease pump
performance and diminish pump service life. Inspect filters every 40 hours.
1. Do not lubricate the oilless compressor! The carbon vanes and grease packed motor bearings do not
require lubrication.
2. Replace intake and exhaust filters regularly.
3. Should excessive dirt, foreign particles, moisture, or oil be permitted to enter the pump, the vanes may
stick or crack. Flushing the pump should take care of this condition. Recommended solvent is Part
Number BAC-1001.

CLEANING INTERNAL COMPRESSOR PARTS

If the compressor is permitted to operate with dirty filters or stored for over 14 days, foreign particles and
moisture can accumulate in the pump chamber. To remove these contaminants, the compressor should be flushed
(cleaned) periodically using an approved safety solvent, Air Systems' Part Number BAC-1001. Flushing should
be done in an open well ventilated area.
1.
Eye protection should be worn when flushing the unit.
2.
To flush the compressor, remove the intake filter assembly and remove the compressor filter element.
3.
Install a blank male plug into one of the quick connect couplings to allow free flow of air through the
compressor system.
4.
While the compressor is running, spray one or two ounces of safety solvent into the compressor's air
intake port.
5.
Flushing should be done in an open area away from sparks and flames. Run the compressor for a minimum
of five minutes before using the compressor with a respirator.
6.
Do not use a flammable solvent or a solvent with a toxicity rating of 500ppm or greater to flush the unit.
Do not use a solvent that leaves a petroleum residue.
Air Systems' manufactured equipment is warranted to the original user against defects in workmanship or materials under normal use for
one year after date of purchase. Any part which is determined by Air Systems to be defective in material or workmanship will be, as the
exclusive remedy, repaired or replaced at Air Systems' option. This warranty does not apply to electrical systems or electronic compo-
nents. Electrical parts are warranted, to the original user, for 90 days from the date of sale. During the warranty period, electrical
components will be repaired or replaced at Air Systems' option.
NO OTHER WARRANTY, EXPRESSED OR IMPLIED, AS TO DESCRIPTION, QUALITY, MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, OR ANY OTHER MATTER IS GIVEN BY AIR SYSTEMS IN CONNECTION HERE-
WITH. UNDER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR LOSS OF PROFITS, ANY OTHER DI-
RECT OR INDIRECT COSTS, EXPENSES, LOSSES OR DAMAGES ARISING OUT OF DEFECTS IN, OR FAILURE OF
THE PRODUCT OR ANY PART THEREOF.
The purchaser shall be solely responsible for compliance with all applicable Federal, State and Local OSHA and/or MSHA requirements.
Although Air Systems International believes that its products, if operated and maintained as shipped from the factory and in accordance
with our "operations manual", conform to OSHA and/or MSHA requirements, there are no implied or expressed warranties of such
compliance extending beyond the limited warranty described herein. Product designs and specifications are subject to change without
notice. Rev 2 12/98
TROUBLESHOOTING (MODEL BAC-20P)
POSSIBLE CAUSE
No lubrication in vanes
Flushing The Compressor

Warranty Disclaimer

-9-
SOLUTION
Check pressure gauge on compressed air source to
ensure proper supply pressure. Turn regulator knob
clockwise to increase air pressure to air motor and
note the gauge pressure on the regulator.
Normal during hot weather
Check oil in lubricator