Switching power in DC
Type A...
5 A
30 VDC
3 A
50 VDC
1 A
75 VDC
0,5 A
125 VDC
0,25 A
250 VDC
Special conditions for safe use
Level switch without heat exchanger
operating temperatures and level switch for submersible application
Type
A..., AA..., B..., BB...
DA..., DAA..., DB..., DBB...
HA..., HAA..., HB..., HBB...
TDA..., TDAA..., TDB..., TDBB...
U...A..., U...AA..., U...B..., U...BB...
The rated cross-section of the conductor to be considered here must be at least 0,5 mm². Connection
cables may not be bared for a distance of more than 3 mm from the terminal screw. Wire end ferrules
must always be used.
4.

Installation and initial start-up

Operating position
During installation the correct operating position must be
observed. For side mounting, observe the "Top" arrow on
the type plate. The float must be able to move freely over
the whole range of movement and must not be restricted
by the tank walls or by fittings in the tank.
Positions where turbulence may be caused by agitators or
by any inlet connections must be avoided.
Process connection flange - industrial series
For switches of the industrial series with flanges according to DIN, ANSI, etc., the gaskets
connecting stud bolts
class and type of gasket and must be tightened to the corresponding tightening torques. Bolts should
be lubricated with grease.
6)
Not included in the scope of supply
In the case of uncertainty on any point, refer to the corresponding standard or consult the
manufacturer.
Level switches incl. flange for high / low temperature applications may not be insulated.
Process connection flange - standard series
For switches of the standard series PN 25 (360 psi), corresponding gaskets are supplied with the unit.
Minimum tightening torques and tightening sequence see following table:
Flange D
01/011
92 mm
7)
Data refer to lubricated studs
8)
High / low temperature application (graphite gasket)
Level switches incl. flange for high / low temperature applications may not be insulated.
www.trimodbesta.com
Type B...
2)
300 mA 30 VDC
3)
, level switch with heat exchanger
3)
3)
4)
4)
5)
6)
used must correspond to the industry standard as regards material, pressure
Gasket
Garlock Blue Gard 3000
8)
Reinz Chemotherm
8 │ 24
2)
Only approximate values can be given for the
allowable charge of gold contacts. These must be
reduced under unfavourable impedance conditions.
The product of current and voltage should not exceed
0,12 VA. The current should be ≤ 300 mA and voltage
≤ 30 V. For alternating currents these values must be
interpreted as peak values.
5)
Limits
Ambient
microswitch T
temperature T
i
-40 to 150°C
0 to
-40 to 150°C
-30 to 120°C
-40 to 150°C
0 to 135°C
-40 to 150°C
-10 to
-40 to 150°C
-30 to
Stud bolts
Stud bolts
carbon steel
stainless steel
7)
18 Nm
22 Nm
4)
for very high or very low
with cable.
Operating
temperature T
A
70°C
0 to 330°C
-30 to 120°C
0 to 400°C
80°C
-196 to 270°C
80°C
-30 to
6)
and
7)
LTB002X │ 2020.06
0
80°C