TROUBLESHOOTING
SYMPTOM
Pilot will not light
Burners won't light
One burner assembly
won't light
Portions of a burner won't
light or have erratic flame
Burner not hot enough
POSSIBLE CAUSE
Gas supply off
Air in lines
Pilot valve not on
Gas supply off
Air in lines
Pilot burner not lit
Control not on
Water in burner
Damaged temperature
control, burner or other
internal component
Burner wet or flame
opening(s) clogged
Temperature control not set
Shutter or nozzle out of
adjustment
Damaged temperature
control, burner or other
internal component
12
SUGGESTED REMEDY
Check main / unit gas valves
Turn pilot valve on. Attempt to light
pilot every 15 sec.
Turn pilot valve on / adjust
Check main / unit gas valves
Turn gas valve on. Attempt to light pilot
every 15 sec.
Turn off gas - allow unit to vent for 5
minutes. Turn gas back on and light
pilot
Turn control knob to ON. Set to desired
setting when lit
Remove burner and dry thoroughly
Contact Authorized Wells Service
Agency for repairs
Clean and dry burner
Adjust for desired temperature
Contact qualified technician for
adjustment
Contact Authorized Wells Service
Agency for repairs