No
Code de rapport
de
CID
Medical Alarms - 100
100
Medical alarm
101
Pendant transmitter
102
Fail to report in
Fire Alarms - 110
110
Fire alarm
111
Smoke
112
Combustion
113
Water flow
114
Heat
115
Pull station
116
Duct
117
Flame
118
Near alarm
Panic Alarms - 120
120
Panic alarm
121
Duress
122
Silent
123
Audible
124
Duress - Access granted
125
Duress - Egress granted
Burglar Alarms - 130
130
Burglary
131
Perimeter
132
Interior
133
24-hour
134
Entry/Exit
135
Day/Night
136
Outdoor
137
Tamper
138
Near alarm
139
Intrusion verified
General Alarms - 140
140
General alarm
141
Polling loop open
142
Polling loop short
143
Expansion module failure
144
Sensor tamper
145
Expansion module tamper
146
Silent burglary
147
Sensor supervision failure
24-hour Non-burglary - 150 and 160
150
24-hour non-burglary
151
Gas detected
152
Refrigeration
153
Loss of heat
Systèmes Magellan de Paradox
No
Valeur de
de
programmation
CID
154
155
01
156
02
157
03
158
159
161
04
162
05
163
06
07
Fire Supervisory - 200 and 210
08
200
09
201
0A
202
0B
203
0C
204
205
206
0D
0E
System Troubles - 300 and 310
0F
300
10
301
11
302
12
303
304
305
13
306
14
307
15
308
16
309
17
310
18
311
19
312
1A
313
1B
1C
Sounder/Relay Troubles - 320
320
321
1D
322
1E
323
1F
324
20
325
21
326
22
327
23
24
System Peripheral Troubles - 330 and 340
330
331
25
332
26
333
27
334
28
Code de rapport
Water leakage
Foil break
Day trouble
Low bottled gas level
High temperature
Low temperature
Loss of air flow
Carbon monoxide detected
Tank level
Fire supervisory
Low water pressure
Low CO
2
Gate valve sensor
Low water level
Pump activated
Pump failure
System trouble
AC loss
Low system battery
RAM checksum bad
ROM checksum
System reset
Panel program changed
Self-test failure
System shutdown
Battery test failure
Ground fault
Battery missing/dead
Power supply over current limit
Engineer reset
Sounder/relay
Bell 1
Bell 2
Alarm relay
Trouble relay
Reversing relay
Notification appliance chk. #3
Notification appliance chk. #4
System peripheral
Polling loop open
Polling loop short
Expansion module failure
Repeater failure
Valeur de
programmation
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
45

Publicité