Operating Instructions
Programming cable PK610
1.
Warning
It is essential for the warnings given in this Operating
Instructions and the operating instructions for the program-
med ...
... SINEAX VK616
... SINEAX V608
... SINEAX V611
... SINEAX V624
... SIRAX V606
... KINAX 2W2
... KINAX WT711
... KINAX WT717
... KINAX SR719
instrument to be strictly observed.
The EC Type Examination Certifi cate is an integral part of
these operating instructions and must be observed!
The programming cable PK610 is only for use in conjunction
with a PC having an RS 232 C serial interface, or with other
suitable devices supplied by Camille Bauer Ltd. No liability
will be accepted in any other cases.
The correct use of the earth connection is described in
the respective operating instructions of the device to be
programmed.
2. Scope of supply (acc. to order)
Programming cable PK610 (1)
Ancillary cable for
SINEAX Type V611, VK616, KINAX 2W2, WT711,
WT717 et SR719 (2)
Ancillary cable for SINEAX Type V608, V624
et SIRAX V606 (3)
Operating Instructions PK610 B d-f-e (4)
1 Ex certifi cate (5)
(1)
(4)
Fig. 1
3. Description
The programming cable PK610 serves to connect the
SINEAX, SIRAX and KINAX transmitters to a PC on which the
PC software V600 plus resp. 2W2 is installed for purposes
of programming the transmitter.
4
(2)
(3)
Betriebsanleitung
Programmierkabel PK 610
Mode d'emploi
Câble de programmation PK 610
Operating manual
Programming cable PK 610
PK 610 B d-f-e
141 987
07.00
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Telefon +41 56 618 21 11
Telefax +41 56 618 24 58
Telex 827 901 cbm ch
Depending on which type is to be programmed, an ancillary
cable with the appropriate connector is necessary.
However, all standard versions (non-Ex) of the above men-
tioned types may also be confi gured. PK610 is designed
as an accessory and features its own intrinsically safe pro-
gramming interface.
The transmitter can be programmed either with or without
the power supply connected on the SINEAX, SIRAX resp.
KINAX.
The connections between
PC ↔ PK610 ↔ SINEAX, SIRAX and KINAX – as well as
the different mounting possibilities, e.g. inside or outside
the explosion danger area – are described in the operating
instructions for each device.
Operating
Instructions
Sineax VK616
Sineax V608-8
Sineax V611
Sineax V624
Sirax V606
Kinax 2W2
Kinax WT711
Kinax WT717
Kinax SR719
Bd: German, Bf: French, Be: English,
Bd-f-e: German, French, English (in 3 languages)
4. Technical data
PC interface connector
Serial interface:
Sub-D connector:
Data transfer rate:
Send signal level:
Receive signal level:
Power consumption:
Intrinsically safe
The PK610 programming cable is suited to short-time use in
(5)
SINEAX, SIRAX and KINAX transducers in "intrinsic safety"
type of protection. The connections are to be separated
after programming.
Type examination certifi cate:
ZELM 99 ATEX 0011 including 1st supplement
Identifi cation:
Weight Programming cable PK610:
Ancillary cable for
SINEAX V611, VK616, KINAX 2W2,
WT711, WT717 and SR719
Ancillary cable for
SINEAX V608, V624 and SIRAX V606
Order Number
Bd
Bf
Be
137 902 142 076 142 125 ---
141 953 142 068 142 117 ---
152 471 152 489 152 497 ---
141 995 142 109 142 159 ---
---
---
---
149 965 149 973 149 981 ---
---
---
---
---
---
---
---
---
---
COM 1, 2, 3 or 4 (RS 232 C)
9 pin
1200 Baud
– 5.6 V / + 5.6 V
– 12...3 V / + 3...12 V
Approx. 80 mW
II (1) G [Ex ia Ga] IIC
Bd-f-e
151 697
151 176
151 259
151 217
140 g
30 g
80 g