General Information; Technical Data; Caring For The Steam Bath/Shower Cabin; Do Not Use - HOESCH PowerLED Baden Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
01

General information

HOESCH brand products are at the forefront of quality, comfort and design. Following the above mentioned instructions
ensures optimal performance and durability of our products. Each product is subject to detailed quality control.
Please, check the completness of the equipment before installation start up. The producer reserves the right to technical
changes! All dimensions are given in mm! All connection dimensions are internal ones! The producer is not liable for any
damages caused by misusing, improper transportation or improper storage of the product. In other respects, the warranty
conditions of HOESCH brand products of jacuzzi and Roman baths type are applicable in their current and valid version.
Caution!
Check the delivery for transport damage! Later claims will not be accepted!
02

Technical data

Power LED for bathtubs
Colour:
chrome bright
Material:
aluminium /ABS
Installation dimension:
 40 mm
Openien:
Outside dimension:  55mm
Voltage:
110-240V, 50/60Hz
Power LED lamps:
Functioning time:
approx. 200.000 h
Power consumption: approx. 3x1W
Beam angle:
120°
03

Caring for the steam bath/shower cabin

Should be rinsed with clean water for a short time immediately after bathing
Glass and chrome surfaces should be wiped with a damp cloth.
Only use gentle cleaners such as a weak vinegar and water solution. Never use cleansing powder or cleaners
containing chlorine.
Do not use microfi ber cloths. They destroy any coatings and may cause the glass to become scratched.

03.01 Do not use ...

Scouring or scraping cleaning textiles or sponges.
Cleaning agents with fl uid acids such as hydrochloric or citric acid.
Scouring agents.
Cleaning agents containing chlorine bleach lye.
04

Electrical connections

Note:All electrical work must be performed by a qualifi ed electrician in accordance with DIN/EN
specifi cations, national regulations and local EVU regulations!
Copper supply cable 3x1mm² should be installed .Based on standards,
chromptherapy bathtubs- as electrical devices of Class I- must have fi xed
installation to electrical line with bipolar switch. For safety reasons power cable
should be connecteed to electrical network with circuit interrupter (RCD device) with
disconnection current 30mA with contacts open at least 3 mm wide.
RCD device should be checked regularrly at least once a month. Minimal thickness
of power cable is 3x1mm²
Electrical connection of bathtub should be prepared in the Area I (device is under
the bathtub), additionally equipotential bonding of bathtub should be ensured). On
bathtub footing there is a clamp marked
connected.
to which equipotential bonding should be
3x1 mm²
L=2500 mm
GB
5