HOW TO ADJUST SETTINGS BY USING THE HAND CONTROLSETS
Press the "S" key for 5 seconds to select between the different settings by using the UP or DOWN key. After you changed a
setting, you have to save the new setting by pressing the "S" key again.
S-1 Unit of measure
S-2 Gyroscope sensor
S-3 Anti-collision sensitivity moving up
S-4 Anti-collision sensitivity moving down
S-5 Display height
S-6 frame operating mode
S-7 Duty cycle
S-8 frame tilt sensitivity
After adjusting all settings you have to press the "S" key again to return to the main menu.
Minimum /Maximum height
To select a minimum height do the following: Move the frame to the desired minimum height. Press the UP & Down key simul-
taneously for about 5 seconds. A beep indicates that the minimum height has been set. (IMPORTANT: You can only select a
minimum height that is below 96 cm)
To remove the minimum height please move the frame to the programmed minimum height, than press the Up & Down key
simultaneously until you hear a beep indicating that the minimum height was deleted.
To set/delete the maximum height please proceed the same way. The maximum height must be more than 97 cm.
TROUBLESHOOTING
Error Code
E1, E6, E7
E2
E4
E5
E8
E11, E21
E12, E22
E13
E14 - E17 | E24 - E27
E18, E28
HOT
Press "S" and then select: 0 for cm, 1 for inches
Press "S" and then select: 0 = off, 1 = least sensitive to 8 = most sensitive
Press "S" and then select: 0 = off (not recommended), 1 = least sensitive to 8
= most sensitive
Press "S" and then select: 0 = off (not recommended), 1 = least sensitive to 8
= most sensitive
Press "S" and then using the up / down keys you can change the display
height if necessary
Press "S" and then select: 0 = constant touch or 1 = one-touch
To deactivate the overheating protection – please do not change!
Press "S" and then select 0 = off, 1 = 0.5°, 2 = 1.0°, 3 = 1.5°, 4 = 2.0°, 5 = 2.5°, 6
= 3.0°, 7 = 3.5°, 8 = 4.0°
Possible Cause
Power failure
Lifting columns out of synch
Handset fault
Anti-collission warning
Desktop not level
Motor fault
Control box failure
Connection problem
Motor failure
Overload protection
Excessive use
E-MORE 2M2S / 2M3S
How To Correct
Reconnect power - switch power source
Perform a reset as described under 1 .
Unplug and plug in the cable of the handset
standard function, no corrective action required
Level the table
Check the motor wire connections
Control box needs to be replaced
Check cables
Motor / lifting column needs to be replaced
Reduce the weight
Do not use for 20 minutes . System will recover
automatically .