Nautilus Schwinn Fitness 460 Manuel Du Propriétaire page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
Console shuts off (enters sleep
mode) while in use
Unit operates but Contact HR
not displayed
Unit rocks/does not sit level
Foot pedals loose/unit difficult
to pedal
Troubleshooting
Check
Main console cable integrity
Main console cable connections/
position
Magnet position (requires shroud
removal)
RPM Sensor (requires shroud
removal)
HR cable connection at console
Sensor grip
Dry or calloused hands
Handlebars
Leveler adjustment on front
stabilizer
Surface under unit
Hardware
Owner's Manual
All wires in cable should be intact. Replace cable
if wires appear crimped or cut.
Confirm cable is securely connected and
properly positioned. Small latch on connector
should line up and snap into place.
Replace flywheel or entire base assembly if you
do not see a magnet.
RPM sensor should be aligned with magnet
and connected to data cable. Re-align sensor
if necessary. Replace if there is any damage to
sensor or connecting wire.
Confirm cable is connected securely to console.
Confirm hands are centered on HR sensors. Hands
must be kept still with relatively equal pressure
applied to each side.
Sensors may have difficulty with dried out or
calloused hands. A conductive electrode cream
such as Buh-Bump™ can help make a better
conduct. Purchase online at medical or large
fitness stores.
Replace handlebars if tests reveal no other
issues.
Level the machine by turning the feet in or out.
Move machine to level area if adjustments do not
compensate for unlevel surfaces.
Tightly secure all hardware on pedal arm, sub
pedal arm, and handlebars.
27
Solution

Publicité

Table des Matières
loading

Table des Matières