STORAGE

Make sure the heater is in off position
Always close the valve of the gas cylinder after use or in case of a disturban-
ce.
Disconnect the gas container from the gas heater.
Store the gas container in a well-ventilated room. Position it far away from
inflammable, explosive or hot materials and preferably not in the home. In
addition it should never be stored in the basement or attic.
Cylinder must be stored out of the reach of children.
Disconnected cylinder must have threaded valve plugs tightly installed and
must not be stored in garage or any other enclosed area. Only store in venti-
lated area!
Storage of heater indoors is permissible only if the cylinder is disconnected
and removed from the heater.
Check the tightness of the gas valve and for damage. If you suspect a dama-
ge, have it changed by your gas dealer.
Never store liquid gas cylinder in a sub-terrain, or at places without adequate
air ventilation.

CLEANING AND CARE

Warning: Make sure the heater is in off position and is cool!
Warning: Do not clean heater with cleaners that are combustible or corrosive.
Wipe off powder coated surfaces with soft, moist rag and soap water.
Remove debris, spider and insect nests from ventilation opening of the cylin-
der enclosure, control compartment, burner and circulation air passageways
of the heater with heavy duty pipe cleaner or compressed air to keep appli-
ance clean and safe for use.
Never clear ports or other openings with toothpicks or other article that will
break and block the ports.