Blue keys coding:
- Adding new user keys: In normal mode pass through the front
reader the yellow key. A short sound will be heard. At this moment
pass the required number of blue keys to be linked. A sound will
be heard per each passed blue key. Finished this process pass
again the yellow key.
- Delete user keys: In normal mode, pass the red key. A short
sound will be heard. At this moment pass the required number of
blue keys to be unlinked. A sound will be heard per each passed
blue key. Finished this process pass again the red key.
5.4. Opening time configuration
The system allows selecting the opening tome of the electronic
lock when passing the user key. This time can be set to 1 second
or 5 seconds. For this adjustment it is required to use the second
jumper:
Opening time: 1 second
Opening time: 5 seconds
With the outdoor panel disconnected, set the jumper shorting the
fourth and fifth pins for 1 second or between the fifth and sixth pins
for 5 seconds.
6. OPERATING INSTRUCTIONS
- Call from outside. After pressing the call buton at the outdoor unit,
the indoor unit will sound and the visitor's image will be seen on the
display(s). Press the button
for 60 seconds time. Once finished the conversation press again
to hang up.
In case of expanded systems with one outdoor unit or two indoor
units:
- After pressing the call button at the outdoor unit with an al-
ready
established
call
between
the second outdoor unit will make a sound.
- Also in case that the call button of the outdoor unit is pressed, all
indoor units will sound and show the image of the visitor until one
indoor unit gets the call with
will enter into standby mode.
98
Detail of the con-
figuration jumper
inside the outdoor
panel
in order to establish communication
indoor
and
outdoor
unit,
. Once this happens all other units
- Call between different indoor units. Press the
other indoor units. The other indoor units will sound without image
on the screen. Press the
button to get and hang up the call again.
- Monitoring the outside. Press the
view the image of the street of the main outdoor unit. Press
again in order to close it. In case any button is pressed.
then image will disappear after 30 seconds. Being in moni-
tor mode it is possible to communicate
In case the user wants to monitor the slave outdoor unit (in case
installed), keep pressed the
until the image is shown.
- Using the user keys
(Only for
KVP 2700 / PE
the system connected, when passing the blue user card clo-
se to the front panel of the outdoor unit (RFID reader), the elec-
tronic lock will be opened for the programmed time.
7. TROUBLESHOOTING
There is no image / audio
• Make sure all connections are done and tight
• Make sure that cameras and speakers are clean from objects
and dust
• Make sure that the volume of the indoor and outdoor units
are correct
• Make sure that any magnetic device is interferring with the
microphones or speakers
The opening system of the door does not work
• Make sure all connections are done and tight
• Make sure that the consumption of the electronic lock can be
offered by the power supply
It is not possible to hear the external sound but the call tone is
heard
• Press the talk button
• Make sure all connections are done and tight
It is possible to hear and visualize the sound from
the outside but it is not possible to communicate
• Press the talk
button in order to establish the communi-
cation in both ways. Just pressing the monitor
only established communication from the outdoor unit to the
indoor unit
• Make sure all connections are done and tight
EN