infaco Electrocoup DSES F3015 Notice D'utilisation page 18

Masquer les pouces Voir aussi pour Electrocoup DSES F3015:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
INFACO may not be held liable for any faults caused by the poor condition
of the gloves.
9
Indication on LED no. 10 on the pruning shears :
works.
Indication reading pruning shear : Fault D07 (only by your dealer via the « interface »).
The permanent red LED on the pruning shear and the fault D-07 displayed in the Data
base show the user that there is a fault in the DSES system.
The secateurs will still operate when the permanent red LED and fault D-07 are
showing BUT the user is no longer protected by the system
In the event of a fault :
1- Press the button no. 10 until the LEDS turn off and disconnect the secateurs at socket no. 11.
2- Check that tongue no. 2 is correctly fixed to the Velcro of the conductive glove no. 8. Check
the condition of the DSES wire.
3- Follow the procedure set out above to check that the DSES is operating correctly.
Special case: the DSES system may still be operating even if the LED on the pruning shear
is red.
If the pruning shears and the DATA base are still indicating an DSES fault, contact the
retailer who sold you the appliance.
DSES fault indications
11
10
permanent red LED and the pruning shear