2VV VENESSE COMFORT Manuel D'installation Et D'utilisation page 5

Table des Matières

Publicité

1.
INSTALLATION
COMFORT SLAVE
Modul
regulace
Comfort
0-10
0-10
0-10
24VAC
VDC
VDC
GND
GND
VDC
1
2
24V
GND
23 24
25 26
25 26
25 26
2
1
2
24VAC
0-10V
0-10V
24VAC
0-10V
MIX. POINT / OUTDOOR
MIX. POINT / OUTDOOR
(two-wire shielded cable)
MIX. POINT / OUTDOOR
POWER SUPPLY
(two-wire shielded cable)
Câble deux fils blindé
Vanne/ Groupe Exterieur DX
Alimentation
Vanne/ Groupe Exterieur DX
Vanne/ Groupe Exterieur DX
UNIT DX
UNIT DX
UNIT DX
MIX POINT
vanne
HEATER/
HEATER/
HEATER/
VENT-EXT
PREHEATER
PREHEATER
24VAC
24VAC
POSTHEATER
PREHEATER
24VAC
REC/BYP
REC/BYP
POSTHEATER
RPM
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
COOL/PUMP
COOL/PUMP
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
COOL/PUMP
GND
PWM
GND
GND
1
1
PWM
GND
1
~
~
0-10V
~
GND
~
+SSR -SSR
0-10V GND
~
~
2
2
0-10V
GND
+SSR -SSR
2
0-10V GND
0-10V GND
(TC)
0-10V
GND
0-10V
GND
GND
25 26 27 28 29
30
31
32
33
25 26 27 28 29
34
35 36 37 38 39 40 41 42 43
30
31
32
33
34
35 36 37 38 39 40 41 42 43
FUSE
(VENT-INT)
FUSE
(PERIPHERY)
72 71
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
72 71
72 71
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
70 69
70 69
LO
L
LO
L
LO
N
RUN
COOL/HEAT
ALARM
RUN
COOL/HEAT
RUN
COOL/HEAT
DEFROST EXTERNAL
ERROR
ERROR
DEFROST EXTERNAL
FIRE
FIRE
230VAC
230VAC
230VAC
OUTPUT
HEAT PUMP
HEATER
OUTPUT
HEAT PUMP
OUTPUT
HEAT PUMP
HEAT PUMP
ON/OFF
HEAT PUMP
ON/OFF
FLAP-INT
FLAP-EXT
W. PUMP
230VAC
EXTERNAL
CONTACT
EXTERNAL
CONTACT
POMPE
WATER
CONTACT
FIRE
CONTACT
FIRE
CONTROL
CONTROL
EXTERNE
EXTERNE
DE CIRCULATION
PUMP CONTROL
OUTPUT
OUTPUT
INCENDIE
OUTPUT
INCENDIE
ON/OFF
ON/OFF
76 75
72 71
4
5 6
63 64
3
62 61
63 64
62 61
6
2
DX = ON/OFF
DX = ON/OFF
7
11
11
12
(Sortie pour unité
(Output for outdoor unit)
Commande
Commande
CMSI
CMSI
exterieure)
á distance
á distance
68 67
68 67
70 69
66 65
68 67
66 65
!
!
defrost
defrost
DX GENERAL ERROR
DX DEFROST
DX DEFROST
8
10
10
9
9
9
(settable)
(settable)
(settable)
(settable)
(settable)
PRESENCE
CAPTEUR
SENSOR
PRÉSENCE
SENSOR
81 82 55 56
230VAC
VCV-B-25-
esclave
1
Control panel
Control panel
boitier de commande
boitier de commande
GND
49 50
49 50
49 50
EXT. SENSOR
EXT. SENSOR
2
EXT. SENSOR
3
3
Capteur Externe.
3
Capteur Externe.
Capteur Externe.
(two-wire shielded cable)
Câble deux fils blindé
Câble deux fils blindé
J1/J2
J1/J2
T-WATER T-WATER T-ROOM
24VAC
POSTHEATER
T-WATER T-WATER T-ROOM
REC/BYP
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
1
~
~
0-10V
GND
+SSR -SSR
-OUT
-OUT
-IN
-IN
2
30
31
32
33
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
44 45 46 47 48 49 50
SWO
SWO
DATA
DATA
DATA
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
1
1
PRESENCE
2
2
PRESENCE
IN GND
REC ERR
DEFROST EXTERNAL
IN GND
REC ERR
REC ERR
ERROR
BOOST
BOOST
FIRE
BOOST
15VAC
15VAC
SENSOR
SENSOR
HEAT PUMP
ON/OFF
CO2/RH/EXT
CO2/RH/EXT
PIR
PIR
EXTERNAL
CONTACT
CONTACT
FIRE
CONTACT
CONTROL
CONTACT
ERROR
EXTERNE
ERROR
INCENDIE
CONTACT
ERREUR
CONTACT
ERREUR
BOOST
BOOST
ON/OFF
8
59 60
63 64
7
62 61
59 60
9
10
11
57 58
57 58
BOOST
BOOST
4
3
5
!
!
13
14
14
12
13
11
12
Commande
CMSI
á distance
66 65
CO
/ RH/VOC
CO
/ RH/VOC
2
2
15
EXTERNAL
15
EXTERNAL
!
defrost
DX DEFROST
10
53 54
53 54
(settable)
2
1
1
2
GND
V+
GND
V+
15VAC
15VAC
2VV. Creating innovative solutions for you and your business since 1995.
E
VCV-B-25-
GTC
GTC
ou
ou
or
ou
or
or
Control panel
boitier de commande
ModBUS RTU via
ModBUS RTU via
ModBUS RTU via
Rs485
Rs485
1
2
3
4
5
J1/J2
T-WATER T-WATER T-ROOM
-OUT
-IN
FILTER
FILTER
FILTER
9
9
9
10
10
10
JP1
JP1
JP1
INT
INT
INT
LED1
LED1
LED1
44 45 46 47 48 49 50
6
SWO
Esclave
1
2
3
4
5
1
PRESENCE
2
IN GND
15VAC
SENSOR
CO2/RH/EXT
PIR
6
7
CONTACT
ERROR
8
CONTACT
ERREUR
BOOST
9
59 60
57 58
10
BOOST
!
13
14
CAPTEUR 0-10V
CAPTEUR 0-10V
SENSOR
CO
/ RH/VOC
CAPTEUR 0-10V
SENSOR
SENSOR
2
16
16
16
15
EXTERNAL
51 52
51 52
51 52
53 54
2
1
0-10 VDC
0-10 VDC
GND
V+
GND
GND
GND
CO
CO
/RH/VOC/EXT
/RH/VOC/EXT
15VAC
2
2
SENSOR
SENSOR
SENSOR
Capteur CO /HR
Capteur CO /HR
S
VCV-B-25-
GTC
Rs485
Raccordement pour unité Esclave
Commande externe – (entrée, ON/OFF)
Thermostat (entrée, NO/NC)
Contact de porte (entrée, NO/NC)
Signal de commande de l'unité Maître
1
2
3
4
5
6
7
8
9
A
0-10 VDC
CO
/RH/VOC/EXT
2
Capteur CO /HR
V
ZV-3 / RT
?
2-way Valve
VENTTIILI
5