Pipe For Gas Connection; Checking Heat Output; Connection With Natural Gas H G20; Checking Primary Air In Main Burners - Lotus cooker FO-1G Instructions Pour L'installation Et L'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The gas connection must be done with steel or copper pipes, or otherwise with flexible steel pipes in compliance with
the national norms, if any exist. Each appliance must be provided with a cut-off cock for rapid interruption of the gas
supply. Once the appliance has been installed, it is necessary to check for gas leaks for the pipe fittings; do not use a
flame for this purpose but a non-corrosive substance such as soapy water or foamy substances as contained in leak-
finder sprays. All our appliances undergo careful testing: the type of gas, the operating pressure and the category are
indicated on the data plate.
NB: The year of the appliance manufacture is shown in item "N" on the data plate. The first two numbers (e.g. 93..)
represent the year of manufacture.
The appliances must be checked in such a way as to verify that the heat output is correct:
The heat output (thermal power) is indicated on the data plate of the appliance.
Firstly, check that the appliance can be used with the type of gas supplied; then check that the indication on the
plate corresponds to the gas to be used. For converting to another type of gas, check that the type of gas complies
with what is stated in this instruction manual.
The pressure is read with a gauge (minimum resolution of 0.1 mbar) inserted in the relative pressure outlet. (figure B
item C).
Remove the hermetically closed screw and insert the gauge pipe.
After reading, put back the screw tightening it hermetically and check for pressure leaks.
Connection for liquid gas G30/G31
The connection pressure for liquid gas is 30 mbar with butane and 37 mbar with propane.
Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied
by the manufacturer.

Connection with natural gas H G20

The connection pressure for natural gas is 20 mbar.
Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied
by the manufacturer.
All the burners are provided with an air regulator which, by means of a bush,can be regulated and fixed with a screw,
enabling the variation of primary air. In the "Burners technical data" table are the approximate values of parameter "h"
(primary air) (see fig. 3). The volume flow of primary air must be regulated so that the flame does not tend to come
away from the burner when it is cold or backfire when the burner is hot.
Burner max 3,5 KW-min 1,2kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
Burner max 5,5 KW-min 1,8kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
GB

PIPE FOR GAS CONNECTION

CHECKING HEAT OUTPUT

CHECKING PRIMARY AIR IN MAIN BURNERS

"BURNERS" TECHINCAL DATA TABLE
12.8 kWh/KG
G30
BUTANE
30 mbar
IE
12.8 kWh/KG
G31
PROPANE
37 mbar
93
93
60
60
0.273 kg/h
0.273 kg/h
27
27
117
117
70
70
0.43 kg/h
0.43 kg/h
27
27
23
3
9.45 kWh/m
st.
G20
NATURAL GAS
20 mbar
145
adjustable
3
0.37 m
st./h
14
180
adjustable
3
0.582 m
st./h
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fo-2gFo-3gFos-1gFos-2gFos-3g

Table des Matières