Routine Maintenance - Oleo-Mac PW 175C Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
• To activate the high pressure water cleaner, to start cleaning, simply operate the lever (26) of the high
pressure cleaning gun.
• The angle of the jet of water can be adjusted via the head (16)
The detergents recommended by the manufacturer are over 90% biodegradable.
Refer to the label on the detergent packaging for use instruction.
• Place the master switch (2) into position "0".
• Remove the cap (19) and taking care not to spill the liquid (maximum capacity 1 l/ 0.26 US gal), fill the
tank (8) with detergent, diluted as required.
• Re-insert the cap (19) on the tank (8).
• Connect the lance hose (15) to the watergun (14) and operate the nozzle head (16) as in
• Start the high-pressure cleaner again, by placing the master switch (2) into position "1" and press the
lever (26): suction and mixing are performed automatically as the water passes.
• To stop the distribution of detergent and return to the high-pressure operation, stop the high-pressure
cleaner by placing the master switch (2) into position "0" and operate on the head (16) as shown in
PICT. 6. 3-a.
INTERRUPTING THE OPERATION - TOTAL STOP
• Release the lever (26) of the high pressure water gun and the cleaner will stop automatically. The cleaner
will start again regularly the next time the lever of the high pressure water gun is pressed.
• Completely close the water supply tap.
• Run the high-pressure cleaner for a few seconds with the lever (26) of the gun pressed to expel any excess
water.
• Place the master switch (2) into position "0".
• Remove the plug from the power socket.
• Eliminate any residual pressure that has remained in the high-pressure pipe (23) by pressing the lever (26)
of the gun for a few seconds.
• Carefully wind up the power cable (1) on the specific cable holder (13).
• Wait for the high-pressure cleaner to cool.
• Carefully wind up the high-pressure pipe (23) making sure there are no kinks.
• Hang the high-pressure pipe on th holder (28) (only
• Place the high-pressure cleaner in a dry and clean location, taking care not to damage the power cable and
high-pressure pipe.
Carry out the operations described in paragraph
MAINTENANCE INTERVAL
On every use
OPERATION WITH DETERGENT
STOPPING
STORAGE
IP 1750 S - PW 175 C

ROUTINE MAINTENANCE

"STOPPING"
• Check the power cable, high-pressure pipe, connectors, gun and
lance pipe.
If one or more parts are damaged, do not use the high-pressure water
cleaner and contact a
(PICT.2 - POSITIONS a AND b)
)
, following the table below.
OPERATION
QUALIFIED TECHNICIAN
(continues on the next page)
.
PICT. 3-b
.
15
GB

Publicité

Table des Matières
loading

Produits Connexes pour Oleo-Mac PW 175C

Ce manuel est également adapté pour:

Pw 190cEfco ip 1750sEfco ip 1900s

Table des Matières