INSTALL LEVELING LEGS

1.
Prepare dryer for leveling legs
To avoid damaging fl oor, use a large fl at piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
2.
Screw in leveling legs
Using a wrench and tape measure, screw legs into leg holes
until bottom of foot is approximately 1½" (38 mm) from
bottom of dryer.
Now stand the dryer on its legs. Slide the dryer until it is
close to its fi nal location. Leave enough room for electrical
connection and to connect the exhaust vent.
For mobile home use
Gas dryers must be securely fastened to the fl oor.
Mobile home installations require a Mobile Home Installation
Hold-down Kit. For ordering information, please reference the
Use and Care Guide.

GAS DRYER POWER HOOKUP

Gas Supply Requirements

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 13" (330 mm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
GAS TYPE
Natural gas:
This dryer is equipped for use with natural gas. It is certifi ed
by UL for use with propane gas with appropriate conversion.
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, please reference the
"Assistance or Service" section of the Use and Care Guide.
Propane gas conversion:
IMPORTANT: Conversion must be made by a qualifi ed
technician.
No attempt shall be made to convert the dryer from the gas
specifi ed on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
IMPORTANT: The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and
Propane Installation Code, CSA B149.1.
9

Publicité

Table des Matières
loading

Table des Matières