Electrical Connections - Bauer LUXO Série Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
5.

ELECTRICAL CONNECTIONS

The gearmotors LUXO3B and LUXO5B can be connected to
the E2 and LOGICM control panels.
The gearmotors LUXO3BH and LUXO4BH can be connected
to the E2H and VIVAH control panels.
The gearmotor LUXO5BH can be connected to the VIVAH
control panel.
The electrical connections and the start-up of the gearmotors
LUXO3B-LUXO5B and LUXO3BH-LUXO4BH-LUXO5BH are
illustrated in fig. 6 and in the installation manuals of the E2,
LOGICM, E2H and VIVAH control panels.
Place the cover [10] back onto the gearbox connecting the earth
cable [J] to the gearbox itself.
(Fig. 6) To increase the protection of the motor cable, a flexible
Ø16 raceway [N] may be used and the associated Ø20 union
[P], not supplied by us. Tighten the screw [F].
6.
MAINTENANCE PROGRAM (every 6 months)
Disconnect the 230 V~ power supply and batteries if present:
-
Clean and lubricate, using neutral grease, the turning pins,
the hinges of the gate and the drive screw
-
Check that fastening points are properly tightened.
Connect the 230 V~ power supply and batteries if present:
-
Check the power adjustments.
-
Check the good operation of all command and safety func-
tions (photocells).
-
Check the good operation of the release (only for
irreversible piston).
-
If the E2H or VIVAH control panel is mounted, check for
battery continuity by powering off and performing several
manoeuvres in sequence. Upon test completion, power
back on (230 V~).
AtteNtiON: For spare parts, see the spares price list.
13
GB
LUXO - IP1684

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Luxo3bLuxo3bhLuxo4bhLuxo5bLuxo5bh

Table des Matières