programming remote controls for the electric lock
J1
J5
J3
1 - PROGRAMMING OPENING LOCK
a) In monostable mode (press on the remote control start the opening, the lock is automatically made).
Press 1 time and release the button P1 to program in monostable mode. The light DL1 ignites, simultaneously to press the key wished by
your remote control to realize the opening.
b) In mode bi - stable (a support on the remote control start the opening, a second support allows the lock.
Press on P1 3 time may release, to program in bistable mode.
The led DL1 lights, then press simultaneously on the key wished on your remote control to realize the opening and the lock.
Then, the Led DL1 goes out, the programming is ended. If the programming fails: DL1 flares up again during 10 seconds. You will have
to begin again the operation.
2 - DEPROGRAMMING
Press on P2 once then to release. The led lights, the key is deprogrammed.
3 - COMPLETE DEPROGRAMMING
Press on P2 during 10 seconds, then to release. The led lights, all the keys are deprogrammed.
Don't throw batteries or out of order products with the household waste (garbage). The dangerous substances that they are likely to include may
harm health or the environment. Make your retailer take back these products or use the selective collect of garbage proposed by your city.
P2
P1
- / ~: Power input, 12Vac or –12Vdc;
+ / ~: Power input, 12Vac or +12Vdc;
J5 Lock coil connector
Ext_ctrl: Input for remote doorphone