Télécharger Imprimer la page

Wiring Details - MANFRED JÜNEMANN T20 Instructions D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

wiring details

(rt)
1
2
1 x Pt100 / 2-wire
(rt )
1
(ws)
2
2 x Pt100 / 2-wire
wiring details
element
Typ J (Fe-CuNi)
Typ T (Cu-CuNi)
Typ K (NiCr-Ni)
Typ E (NiCr-CuNi)
Typ N (NiCrSi-NiSi)
Typ S (Pt10Rh-Pt)
Typ R (Pt13Rh-Pt)
Typ B (Pt30Rh-Pt6Rh)
Between 850 and 950 °C type K involves the risk of selective chrome oxidation. If the service temperature
is continually fluctuating within this area, we recommend sensor type N.
element
Typ L (Fe-CuNi)
Typ U (Cu-CuNi)
1 x Pt100 / 3-wire
(r t)
5
(sw)
3
(rt )
1
4
(ge)
2
2 x Pt100 / 3-wire
1 x thermocouple
thermocouples
thermocouples
(rt)
1
(rt)
2
3
(sw)
6
(sw)
3
(ge)
4
IEC 584-1
min.
max.
-210°C
760°C
-270°C
400°C
-270°C
1370°C
-270°C
1000°C
-270°C
1300°C
-50°C
1760°C
-50°C
1760°C
+100°C
1820°C
DIN43710
min.
max.
-200°C
900°C
-200°C
600°C
(rt)
1
(rt)
2
(ws)
4
(ws)
3
1 x Pt100 / 4-wire
Legende
rt = red
ws = white
sw = black
ge = yellow
2 x thermocouple
+ connection - connection
black
brown
green
violet
white
lilac
orange
orange
grey
+ connection - connection
red
blue
red
brown
Quality for the
future
5

Publicité

loading

Ce manuel est également adapté pour: