Firmware Upgrade - Acksys WLg-IDA/S Guide D'utilisation Rapide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SERIAL SERVICE TYPE SELECTION
The way you will use the product determines the serial service to activate.
Get help from the information provided on the "BASIC" page, "Serial port"
submenu.
If you are using the MODBUS protocol:
• Use the "MODBUS/TCP master" service if the serial port of the product is
tied to the MODBUS master (the supervisor);
• Use the "MODBUS/TCP slave" service if the serial port of the product is
tied only to slave devices.
If you want to access a remote serial device in the same manner as a
local port (including control signals):
• usually the "Virtual COM (VIP)" service on the device side and a COM port
redirector like VIP on the computer will do that.
If you want to exchange serial data (no control signals) between two or
more devices through the network:
• use the « UDP raw port server » service on all the serial attachments
involved;
• if you have only two devices, and not losing data is more important than
speed and network bandwidth, you must use « raw TCP server » on one
side, « raw TCP client » on the other side.
If you want to write a SOCKET application to access remote devices:
• use "Virtual COM (VIP)" if you must configure control signals remotely;
• use « raw TCP server » to handle unrelated devices;
• use « UDP raw port server » to broadcast to several devices at the same
time.
If you want a remote serial device to call into your application:
• use « raw TCP client ».
Getting the updates
The firmware upgrades are available on our web site in the form of a file with
a ".bin" extension or a compressed file containing a ".bin" file. You must copy
this file on your computer before proceeding to upgrade.
Upgrade methods
 With Acksys NDM: select one or more products, click "Upgrade" and
follow the instructions. (Remark: Acksys NDM uses a TFTP server
embedded in the product, which is allowed by default in the "Tools" menu,
"firmware" submenu.
 With the product WEB interface: In the "Tools" menu, "firmware"
submenu, follow the instructions.
In case of power breakdown during upgrade
Interrupting the upgrade may result in an invalid firmware. In this case the
product reboots with a special firmware called "emergency upgrade".
This mode allows firmware reload. It has the following characteristics:
- The DIAG indicator blinks quickly and evenly
- The serial port cannot be used
- The Wi-Fi interface acts as an access point, B/G automatic channel
- An embedded DHCP server eases connection from the PC
- The advertised SSID is "emergency-upgrade"
- The product appears in Acksys NDM as "emergency upgrade"
- The WEB interface has only one page, which allows you to reload the
firmware.

FIRMWARE UPGRADE