Problems
The appliance does
not work
Temperature inside
the appliance is not
low enough

TROUBLE-SHOOTING

Possible causes

Electric circuit rupture
Incorrect setting of the
adjustment knob
The ambient tempera-
ture is higher or lower
than the N-ST climate
range
The appliance is located
at the sunlit place or
near the heat sources
Too much warm food
loaded at a time
Internal air circulation
hindered
The air circulation at the
back of the appliance is
hindered
Too much white frost
accumulated on the
freezing elements
The door of the frid-
ge/freezer are opened
too often and/or remain
open for too long
The door does not close
completely
Remedies
- check whether the plug is properly inserted
into the socket
- check whether the power cable of the
appliance is not damaged
- check whether there is voltage in the
socket, by plugging another appliance, e.g.
a night lamp
- check whether the appliance is switched
on by setting the thermostat to a position
above 0.
- reset the knob to a higher position
- the appliance is adapted to operation in
the N-ST climate range.
- move the appliance to another place.
Observe the guidelines contained in the
manual
- wait 72 hours until the food becomes cool
(freezes) and the required temperature is
reached inside the chamber
- place the food and containers in such a
way that they do not touch the rear wall of
the fridge
- move the appliance min. 30 mm away
from the wall
defrost the freezer chamber
- reduce the frequency of opening the door
and/or shorten the time when door remains
open
- place the food and containers so that they
would not interfere with door closed
53