In the event of a hazard arising from the unintentional reset of the thermal
switch, this equipment should not be powered by an external connecting device,
such as a time switch, or a disconnector connected to the circuit, which is
regularly switched OFF and ON during use.
VALVE PARAMETERS:
-S-V-3-½" - Three-way valve ½" with
actuator
-S-V-2-½" - Two-way valve ½" with
actuator
12 CONNECTION OF HYDRAULIC INSTALLATION
PIC. 12.1 Delivery of the heating medium
16/52 User Instructions
Class of protection: IP20
Supply voltage:1N ~230V/50 Hz
Max. Medium temperature: + 93°C
Max. Operating pressure: 2.1Mpa
S-V-2 1⁄2 "Kvs: 3.0 m
S-V-3 1⁄2 "Kvs: 3.4 m
Motor running time: 18 s
A – Return pipe water supply
AB – Valve water supply
B – Exchanger water supply
PIC. 12.2 Bleeding / air release valve
CAIROX
3
/h
3
/h