Texecom Premier Elite Série Guide De L'utilisateur page 4

Masquer les pouces Voir aussi pour Premier Elite Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Premier Elite Series User Guide

6.
Press
,
The exit tone will sound (if silent arm has not been selected)
7.
Leave the premises When the system has armed, the exit tone (if sounding) will stop
To DISARM the System
The entry time is divided into two sections, the Entry time and the 2
and the 2
nd
Entry time will start. If the 2
It is perfectly normal for the 2
1.
Enter the premises via the designated entry point The entry tone will start
2.
Enter a valid User code
To DISARM the System When Not in Entry
1.
Enter a valid User code
2.
Press
To CANCEL the Exit Mode
Once the exit mode has been started you should leave the premises immediately, however, if for some reason you decide not to leave, the
exit mode must be cancelled.
1.
Enter a valid User code
2.
Press
The exit tone will stop.
To CLEAR an Arm Fail
When the system tries to arm with zones active (open), the internal sounders will sound and the external strobe will be flashing to
indicate a problem. For details on preventing an Arm Fail condition, please refer to page 7.
If you were not present when the Arm Fail occurred or you do not clear the Arm Fail, the internal sounders will continue to sound and the external strobe will
continue to flash.
1.
Enter a valid User code
to flash and the number of the zone that caused the Arm Fail will be displayed.
2.
Enter a valid User code
To SILENCE an Alarm
When an alarm occurs on the system, the internal and external sounders will normally sound for a pre-programmed time (normally 15
minutes).
If you were not present when the alarm activated, the internal and external sounders may have already stopped but the external strobe will still be flashing.
When alarm information is being displayed, pressing the SCROLL key will slow down the display and also allow manual scrolling through the events.

Enter a valid User code
the alarm will be displayed. The alarm now needs to be reset.
To DISPLAY the cause(s) of System Alerts (Alarms)
When silencing an alarm or unsetting the system after an alarm, the number of the zone(s) will be displayed on the keypad. If several
zones were triggered, the display will scroll through each in turn.
After noting the cause of the alarm, the system can be reset as described in 'RESET After an Alarm' below.
System Alerts
When the system has faults to display, or has not been reset after an alarm condition, the display may show 'SYSTEM ALERTS'.

Enter a valid User code
Any alarms or faults will be displayed. If several fault or alarm conditions have been triggered, the display will scroll through each in
turn.
After noting the cause of the alarm or fault, the system can be reset as described in 'RESET After an Alarm' below.
Some action may be required to clear the cause of the alarm or fault in order to successfully reset the panel.
4
or
followed by
nd
Entry time expires, an Intruder alarm will occur (all internal and external sounders).
nd
Entry time to be programmed as zero, in which case, an Intruder alarm will occur as soon as the Entry time expires.





The internal and external sounders will stop and the number of the zone that caused
or
(24/48/88/168) or
nd
Entry time. If the Entry time expires, an Internal alarm will occur
The entry tone will stop
The internal and external sounders will stop, the external strobe will continue
and press
(640)to PART arm the areas
INS555-2

Publicité

Table des Matières
loading

Table des Matières