3. Commissioning
The cartridge gun PowerLine II is supplied ready to use. Before use, remove the protective cap from the cartridge cylinder. The
following checks should be made regarding the functionality.
At the start of use, check that the working cylinder and the cartridge cylinder are firmly screwed together.
Connect the compressed air and check the operation of the pressure regulator. The internal operating pressure can be set by
rotating the blue cap of the regulator. This is displayed on the manometer in the handle.
Check the operation of the trigger valve with the compressed air connected.
4. Operation
Cartridge insertion and exchange
Unscrew the retainer nut from the cartridge cylinder and insert the cartridge prepared as instruct-
ed by the manufacturer. If required, the piston rod of the gun must be pulled back; the cartridge
must be inserted to make contact with the tooth lock washer on the back.
Use only undamaged cartridges.
Now screw the retainer nut on to the cartridge cylinder. After meeting the seal, increased force is
required for screwing. Continue to turn the retainer nut until the cartridge inside is correctly
clamped.
Only operate the gun with the retainer nut fully screwed on.
Ensure that the cartridge is located centrally in the cylinder.
Setting the working pressure
Connect the compressed air and set the specific working pressure required for the cartridge as
described above. When doing this, please note:
Low-viscosity materials
low working pressure required
Turn the regulator knob in the – direction
High-viscosity material, 2-component cartridges with mixer
Turn the regulator knob in the + direction
To ensure continuous dispensing, the working pressure should be correctly set before starting the dispensing.
GB
- 12 -
Tooth lock
Cartridge