OTHER FEATURES

Voltage Probe

Probe Release
Earth Stud
Voltage Probe
Use the Voltage probe in hard to reach areas such as Cut
Out Switches. Touching the probe on a terminal will ac vate
the Fault Finder to display a voltage reading.
Note: You should not use the voltage probe for current
readings as they will not be accurate. The fence line needs
to fl ow through the measurement slot to obtain accurate
current readings.

Earth Lead Accessory

The Fault Finder has been designed to give an accurate
measurement of voltage across a wide range of condi ons. If
greater accuracy is desired the earth lead should be used.
If you have an earth return fence system then use the earth
lead and place it on the earth wire.
In all other instances, placing your thumb on the earth stud
will be suffi cient (this will not give you a shock).
Low Ba ery
Displays when ba ery needs replacing
6
Earth Lead
Power bu on
Turns on the
Fault Finder
Fence Pulse
Blinks whenever a fence
pulse is detected