Installation
Note: If the unit has not been
stored or moved in an upright
position, let it stand upright for
approximately 12 hours before
operation. If in doubt allow to
stand.
1. Remove the appliance from the packaging.
Make sure that all protective plastic film and
coatings are thoroughly removed from all
surfaces.
2. Maintain a distance of 20cm (7 inches)
between the unit and walls or other objects for
ventilation. NEVER LOCATE NEXT TO OR
NEAR A HEAT SOURCE.
Note: Before using the appliance
for the first time, clean the
shelves and interior with soapy
water.
Table of Controller Parameters
The operating parameters of this appliance have been preset for optimum performance and to maximize
the life of the appliance.
Note: The range refers to controller not machine capability, e.g. these units will function
between 0°C and 12°C only so parameters E1 and E2 should be set between 0°C and 12°C .
Display
E1
Lower set temperature
E2
Upper set temperature
E3
Temperature buffer
E4
Temperature buffer time delay
E5
Fixed parameter
E6
Fixed parameter
F1
Defrost period
F2
Defrost interval
F3
Defrost temperature
F4
Centigrade/Fahrenheit
4
CD229-CD230_ML_A5_v5_20210106.indb 4
CD229-CD230_ML_A5_v5_20210106.indb 4
Operation

Control Panel

The control panel is located below the doors on the
rear of the appliance.
Turn On
1. Close the doors of the appliance.
2. Connect the appliance to a mains power
3. Press the

Setting the Operating Temperature

1. Press the SET button. The display will flash.
2. Press the
3. Press the SET button to store the temperature.
Parameter
0°C
12°C
4°C
3 minutes
0
00
25 minutes
6 hours
20°C
0°C
supply.
button to turn the light On or Off
as required.
or
buttons to display the
required temperature.
Preset Value
-20°C to 2°C
2°C to 45°C
1°C to 10°C
0 to 10 minutes
DO NOT CHANGE
DO NOT CHANGE
1 to 60 minutes
1 to 24 hours
0°C to 22°C
°C/°F
Range
2021/1/6 15:35