Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20

Fault Finding

The following table gives checks and actions that you can perform if your machine does not operate correctly.
If these do not identify/remedy the problem, contact your service agent.
Warning: Switch off and remove plug from mains before investigating fault.
Symptom
Motor refuses to start
Motor stops
Fuses blow
Excessive working pres-
sure
Pressure pulsating
Pressure too low, but
steady
Note: Several types of ac-
cessory will normally de-
liver a lower pressure
Motor starts up but no
working pressure
The pressure washer
starts irregularly by itself
Water leaks from ma-
chine
18 • F016 L70 370 • TMS • 06.09.05
Possible Cause
Plug not connected
Mains socket faulty
Fuse faulty/blown
Extension cable damaged
Motor protector has activated
Frozen
Fuse faulty/blown
Wrong mains voltage
Motor protector has activated
Fuses faulty/blown
Nozzle partly blocked
Air in the inlet water supply hose/pump
Inadequate water supply
Water strainer blocked
Water supply hoses squeezed
High pressure hose too long
Nozzle worn
Start/stop valve worn
No water supply
Water strainer clogged up
Nozzle clogged up
Pump/power gun leaky
Leaking pump
English - 6
Remedy
Connect plug
Use another socket
Replace fuse
Try without extension cable
Allow to cool for 5 minutes
Wait for pump/water supply hose/ac-
cessory to thaw
Replace fuse
Check that mains voltage corresponds
to specifications on the model tag
Allow to cool for 5 minutes
Change to a mains supply higher than
the pressure washer amp consump-
tion
Clean nozzle
Allow pressure washer to run with
open spray handle and nozzle at low
pressure until regular working pres-
sure is obtained
Check that the water supply corre-
sponds to specifications. The mini-
mum specification for the water supply
hose is 1/2" or 13 mm diameter
Clean water strainer
Straighten out kinked water supply
hoses
Dismount high pressure extension
hose. Retry (extension hose max. 7 m)
Change the nozzle
Activate trigger five time in quick suc-
cession
Connect water supply
Clean the water strainer
Clean nozzle
Contact your Bosch Service Centre
6 drops per minute are permissible. In
case of more serious leakage, you
should contact your Bosch Service
Centre

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquatak ecoAquatak 100Aquatak 100 plus

Table des Matières