Electrical Connection; Assembly Of Cover - J.E. StorkAir CML Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical connection

The CML(e) is fitted with a 5-core cable for the electrical
connection. The system has 3 settings as standard
and must be connected according to the enclosed
diagram. The unit should be connected according
to the applicable standards. The system is not suited
for connection to threephase power supplies.
PE N L
230V 50Hz
Maintenance
Before inspection/maintenance of the fan is started, it
must be electrically isolated. The fan should be checked
once a year, and, if necessary, cleaned. The fan section
must be dismantled for this purpose and cleaned with
soap and water. Prevent water or soap from entering the
motor. The ventilation valves can be cleaned with soap
and water. For this purpose, the valves are removed
from the duct system. Take care not to change the
valve settings and not to switch the ventilation valves.
(Dis)assembly of various parts
Disassembly of fan section
Insert the screwdriver (approx. 8mm) into the slot
of the cover, put a finger under the cable. Free the
click connection by moving the screwdriver outwards
or a quarter turn while pushing the cover (cable)
upwards. The click connection unclicks. Then free
the other click connection (see drawing 1).
Assembly of fan section
Place the fan section as squarely as possible in the
housing and apply pressure so that it clicks properly
and securely. Take care to position the slots in the
cover squarely above the fingers of the click joint.
L
M H
1
Cover
The identification plate and integrated condenser
block are located below the cover.
Disassembly of cover
Put the fan section on the cover, with the fan wheel
pointing upward. Free the click connection by moving
the screwdriver outwards or a quarter turn while
holding the fan section cover (see drawing 2).

Assembly of cover

Position the cover squarely onto the motor plate.
Check whether the cable recess and the guiding
ridges are in the right position. Push the cover
onto the motor plate until it snaps into place.
2
Disassembly of condenser block (CML)
Insert a screwdriver under the click connection to
lift and remove the condenser block.
Assembly of condenser block (CML)
Position the condenser block below the hooks on
the outer side of the motor plate. Ensure that the
condenser block is well within the projections.
Then push the block until it clicks into place (see
drawing 3).
9
3