Tefcold UF50G Manuel D'utilisation page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Start-up of the cabinet
Before use, we recommend that the cabinet is cleaned, see the section on maintenance
and cleaning.
Important !
If the cabinet has been vertically placed during transport, please wait 2 hours before
starting up the cabinet.
2 distance pieces are included for mounting on the back of the freezer. These ensure that
the freezer is sufficiently ventilated. They should be fitted in the predrilled holes as shown
on the photo.
Thermostat
The temperature can be adjusted by using the thermostat button at the back of the
cabinet.
Set to position 5 on the thermostat scale. Place a thermometer approx. 10 cm inside the
cabinet on the top shelf and check the temperature once it has achieved steady
conditions. Turn the thermostat button clockwise if the temperature is too high or anti-
clockwise of the temperature is too low.
Defrosting
A layer of frost gradually forms inside the cabinet. When the layer is 3 mm thick it should
be scraped off using a plastic scraping implement, and removed from the cabinet without
switching off. The cabinet is then ready for use again. If the cabinet is dirty inside, it
should be switched off at the mains so the layer of frost can melt before cleaning
commences.
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Uf100gUf50gcpUf100gcp/heated door

Table des Matières