Les langues disponibles

  • FRANÇAIS, page 5
CM4 Series Instruction Manual
Avoid excessive shock or vibration.
If series and/or parallel combinations of outputs exceed safe voltage and/or energy levels, the final equipment manufacturer must
provide the appropriate protection for both users and service personnel.
Parameter
Details
Input to Output (2 MOPP)
Input to J2 standby control (2 MOPP)
Isolation Voltages
Input to Chassis (1 MOPP)
Global signals (J3) to Output/Chassis
Output to Output/Chassis
Earth Leakage Current
Normal Condition, 264Vac, 63Hz, 25°C
Touch Leakage Current
Normal Condition / Single Fault Condition
Parameter
Equipment class
Overvoltage category
Material Group
Pollution degree
Parameter
Air
Operational limits subject to appropriate de-ratings
Temperature
Humidity
Altitude
EN 60068-2-27: Half sine, 3 axes, 3 positive & 3 negative
Shock
810G: Method 516.6, Procedure IV, Transit drop
EN 60068-2-6: Sine,10 – 500 Hz, 3 axes, 1 oct/min., 10 cycles each axis
EN 60068-2-64: Random, 5 – 500 Hz, 3 axes, 30 min.
810G: Method 514.6, Procedure I (General Vibration)
Vibration
Category 4 (Trucks & Trailers, Composite wheeled vehicle), Figure 514.6C-3.
Category 7 (Aircraft, Jet cargo), Figure 514.6C-5 General exposure
Category 24, (All, Minimum integrity) Figure 514.6E-1
Thermal
MIL-STD-810G Method 503.5 Procedure I-C. Multi-cycle. 3 shocks.
shock
Notes
1.
Some specifications may not be met below -20°C.
Note: All output voltages/variants may not be available as standard units, refer to datasheet for standard product range. These (and
other variants) may be available as non-standard or custom units, please contact our sales team for details.
14
Specifications

SAFETY SPECIFICATIONS

INSTALLATION SPECIFICATIONS

Details
I
II
Ingress protection rating
IIIb (indoor use only)
2
Intended usage environment

ENVIRONMENTAL SPECIFICATIONS

Details
Relative, non-condensing
Parameter
Flammability Rating
ROHS compliance
Non-
Operational
Min
Max
-51
+85
5
-200
5000
-
50, 11
-
-
-
0.02,2.56
-
-
-
-
-51
Max
Units
Notes
4000
V
AC
4000
V
AC
1500
V
AC
500
V
DC
500
V
DC
200
uA
20/200
uA
Details
94V-2
IP10
2011/65/EU
Home Healthcare
Operational
Min
Max
(1)
-40
70
95
5
95
-200
3000
-
30,18
-
-
-
-
2
0.0122,1
g
-
-
-
-
-
-
-
-
-
85
-
-
260417-6
Aug 2019
-
-
-
-
-
-
-
Units
°C
%
m
g, ms
-
g
2
/Hz, g
RMS
-
-
-
-
-
°C

Publicité