Samsung BRR20R121 Série Manuel D'utilisation page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Ventilation system of the cabinet
As shown in the figure, the air entering the refrigerator circulates along the ventilation
path (see the arrow direction) of the cabinet. The cabinet must have at least 360 cm
example WxH: 480 mm x 75 mm) of space both for the air inlet and air outlet. Also, the
cabinet must have a rear vent of at least 360 cm
space at the rear bottom.
Air inlet
A
1
1
1
1
Air outlet
A
B
B
1
1
1
1
C
(for example WxH: 480 mm x 75 mm) of
2
1
The air inlet must be positioned in one of
the examples below, or a similar position,
depending on your cabinet type.
A. A ventilation hole included in the
cabinet.
B. A cabinet with feet.
The air outlet must be positioned in one of
the examples below, or a similar position,
depending on your cabinet type.
A. Immediately above the refrigerator
with an optional vent grille
B. Close to the cabinet ceiling
C. Above the refrigerator with a
separately built-in vent
CAUTION
Regardless of the cabinet design, the air
ventilation system must not be blocked by
any kind of installation.
(for
2
360 cm
2
English
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Brr7gr121 série

Table des Matières