Codes D'erreur - Mo-vis Multi-Joystick Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Codes d'erreur

Fault
CPU Error RAM
CPU Error FLASH
CPU Error EEPROM
Run Error Scheduler
Code Error Framework
Code Error Application
MSP Command Corrupt
MSP Command Unknown
MSP Sub Command
Unknown
MSP Argument Invalid
MSP Device Not Ready
MSP Device Wrong State
PCB Test Failed
Assembly Test Failed
Field Test Failed
Test Flag Check
ADC
Output
Reference
Communication
Joystick (Sensor)
Accelerometer
36
Reason
CPU consistency check failed.
CPU consistency check failed.
CPU consistency check failed.
Firmware consistency check failed.
Firmware consistency check failed.
Firmware consistency check failed.
Corrupt command was received.
Unknown command was received.
Unknown Sub Command was received.
Invalid argument received.
Device as not ready to receive an MSP
command.
The device is not able to receive a
command in the current device state.
Factory test failed.
Factory test failed.
Field test failed (Calibration).
One or more test flags not set.
ADC Conversion error.
The OMNI outputs are out of spec.
The OMNI reference is out of spec.
Communication with the sensor
(joystick failed)
The Sensor (Joystick) faulty
The Accelerometer fails
Required action
Replace PCB
Replace PCB
Replace PCB
Update Software or Replace PCB
Update Software or Replace PCB
Update Software or Replace PCB
Connection with the PC (Configurator
program) went wrong, try again.
Connection with the PC (Configurator
program) went wrong. Update Firmware or
update Configurator Software. Try again.
Connection with the PC (Configurator
program) went wrong. Update Firmware or
update Configurator Software. Try again.
Connection with the PC (Configurator
program) went wrong. Update Firmware or
update Configurator Software. Try again.
Connection with the PC (Configurator
program) went wrong. Update Firmware or
update Configurator Software. Try again.
Connection with the PC (Configurator
program) went wrong. Update Firmware or
update Configurator Software. Try again.
A fault occurred during factory testing.
A fault occurred during factory testing.
A fault occurred during field testing
(Calibration).
Redo tests and/or replace PCB.
Check OMNI Cable, replace PCB interface
Check OMNI Cable, replace PCB interface
Check OMNI Cable, replace PCB interface
Check cable to sensor (joystick) and/or
replace sensor (joystick)
Check cable to sensor (joystick) and/or
replace sensor (joystick)
Replace PCB interface

Publicité

Table des Matières
loading

Produits Connexes pour Mo-vis Multi-Joystick

Ce manuel est également adapté pour:

P002-61

Table des Matières