Introduction
These instructions must be used in con-
junction with the instructions for the door
drive. Carefully read and implement all
instructions prior to installation and oper-
ation.
Intended application
Intended use
The light barrier is used as an additional
safety device for operating an „Ultra",
„Ultra excellent", „Ultra excellent quick"
or „Magic" door drive.
Any other use is deemed improper. The
manufacturer accepts no liability for
damage resulting from such use.
Manufacturer
Cardo Door Production GmbH
Normstahlstr. 1-3
D-85368 Moosburg
Instructions, Remarks
CAUTION
Indicates working or operating proce-
dures which have to be complied with
exactly in order to exclude danger to
persons.
ATTENTION
Contains information which must be ob-
served in order to prevent damage to the
equipment.
NOTE
Highlights technical requirements to
which particular attention must be paid.
Cross-references
In the text section, cross-references are
made to the mounting plan as follows:
[12] =
Diagram No., e.g. 12
[21-] =
Diagram No., e.g. 21 and sub-
sequent diagrams
(21) =
Location No., e.g. 21
Lichtschranke
Safety
It is vital that all the instructions
are followed carefully to ensure per-
sonal safety. Please keep the instruc-
tions to hand for future reference.
Remove the mains plug before
working on the door drive.
Tools [1]
[1]
Ensure that you have the neces-
sary tools to hand.
Scope of supply [2]
Pos. Description
1
Light barrier
400908470000
1.1
Transmitter (Tx)
1.2
Receiver (Rx)
1.3
Cable screw connection
1.4
Connecting plate
2
4-core stranded conductor,
10 m
3
2-core stranded conductor,
13.5 m
4
Connecting angle
5
Flat-head screw M6x15
6
Hexagonal head screw M6 T-14465
7
Sheet metal screw 4x8
Installation
[3]
Drill connecting holes in the
frames.
The connecting holes must be of
equal height.
Fix the connecting plates (1.4) to
the connecting angles (4).
[4]
Fix the connecting angle (4) to the
frames.
[5]
Slide the transmitter (1.1) and re-
ceiver (1.2) onto the connecting
plate (1.4).
Remove the mains plug of the
door drive.
T-14921 04/2011
[6]
Connect stranded conductors (2)
and (3) to the transmitter (Tx) and
receiver (Rx) according to the wir-
ing diagram enclosed. Attach the
cable to the wall and ceiling and
plug in the Western plug on the
door drive.
Adjust the light barrier
Plug in the mains plug of the door
drive. The green LED display on
the transmitter (1.1) must be illumi-
nated.
Do not look at the infrared beam
on the light barrier as this may dam-
age the retina.
[7]
Point the transmitter (1.1) towards
the receiver (1.2):
Article No.
Turn the screw marked „ORIZ" to
adjust the horizontal position; turn
the screw marked „VERT" to adjust
the vertical position.
Screw the cover onto the transmit-
ter and receiver, and remove pro-
tective film.
T-14479
Function test
T-14480
Interrupt the infrared beam several
T-14907
times by hand.
T-14466
Operate the door drive using the
hand-held transmitter or wall
switch.
T-14464
The light barrier does not work dur-
ing opening. On closing, the door drive
must stop as soon as the light beam is
interrupted. The closing procedure can-
not be activated with an interrupted light
beam.
Disposal
The national and local regulations and
statutes for disposal are to be followed.
English
Electric and electronic
parts have to be recy-
cled and are not to be
discarded in residen-
tial waste!
11 / 15