RAVAK SUPERNOVA SRV2-S-75 Instructions De Montage page 4

Masquer les pouces Voir aussi pour SUPERNOVA SRV2-S-75:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
GB
ASSEMBLY INSTRUCTIONS
1.
The delivery consists of: 2 pcs of part SRV - S width 750, 800, 900 or 1000 mm and 1 pc of fixed wall PSS(APSS) width
750, 800, 900 or 1000 mm (+ corner connection profile). Before assembly check the completeness of delivery.
2.
The assembly is done outside the shower tray. Position the plastic corner connections into the frame, drill the holes
Æ
2,6 mm and fix the connections using screws
3.
Sealing of the closed door is made by two magnetic profiles. If these magnetic profiles do not fit to each other, remove
one of them gently using a screwdriver, turn it rounad and push it back again.
4.
Position the shower corner onto the shower tray, adjust the correct position and mark the holes on the wall.
5.
Remove the wall connecting profiles from the frame and mark the holes on the wall.
6.
Drill the holes, insert dowel plugs
7.
Fix the wall connection profiles to the wall using screws
8.
Position the assembled shower corner onto the shower tray, slide it into the wall connecting profiles, adjust and try the
correct function of the door.
9.
Use the prepared holes of the wall connecting profiles and drill holes
Æ
Secure it with screws
10.- 11.
Use silicone sealing compound. Seal between the tiles and the wall connecting profile on the inside and on the
outside. Seal only on the outside of the lower running track. The a. m. operation must be done by means of the silicone
RAVAK PROFESSIONAL which has an excellent cohesion. If another putty is used you run a risk it will not be water
resistant.
12.
Both shower tray and polystyrene glass are protected by thin plastic foil. Do not forget to remove it before using the
enclosure.
13.
The assembly of shower enclosure with fixed wall.
The assembly of a shower corner combined with a fixed wall is similar to the assembly of the basic version. After the
assembly of the shower enclosure the fixed wall can be attached using the angle connecting profile. Remove one wall
connection profile from the frame and slide the angle connecting profile instead of it. Slide the wall connecting profile onto
the frame of the fixed wall.
The two halves of the shower enclosure can be installed either right or left (turn upside down). Textured side of glass
facing outwards.
Put the complete shower enclosure onto the shower tray, mark the position of the wall connecting profiles on the wall and
mark the position of the frame inside the angle connecting profile.
Further assembly is done outside the tray. Remove the fixed wall, drill the holes into its frame and connect it together with
angle connecting profile using screws
Use the prepared holes of the wall connecting profiles and angle connecting profile and drill the holes
frame. Connect it screws
IMPORTANT INFORMATION!
When maintaining the shower bath, only wipe the painted parts, glass and plastic, using a fine cloth and normal
household detergents. Never use abrasive pastes, solvents, acetones or similar substances. The manufacturer is not
responsible for damage caused by inappropriate use, installation or maintenance of the product. The manufacturer is
entitled to continuous innovation of the product. For all other information concerning the mounting, use and maintenance,
ask your salesperson. The guarantee is 24 months from the date of sale. The manufacturer recommends: RAVAK
ANTICALC CONDITIONER - is a preparation which perfectly renews and maintains all the qualities of the RAVAK
ANTICALC protective coating; RAVAK CLEANER - works to remove old and dried-on debris from glass surfaces, shower
frames, enamel and acrylic bathtubs, washbasins and water taps; RAVAK DESINFECTANT - is a special preparation with
considerable anti-bacterial and anti-fungal effects.
Æ
Æ
8 mm and tap them gently by using a hammer.
3,5/13 mm.
Æ
3,5/13 mm. Further follow the basic assembly instructions.
Æ
3,5/13 mm.
3,5/6,5 mm.
Æ
4/40 mm.
SRV2 - S, ASRV3
Æ
2,6 mm into the frame of the shower corner.
Æ
2,6 mm into the

Publicité

Table des Matières
loading

Table des Matières