Erase master link:
Use this function to erase master code;
In 'Run mode', press (►) key during 10 seconds to enter in RF initialization mode for master, then the red
LEDS of zone are blinking;
Then user has to press the 2 keys (◄) and (ok) during 5 seconds; (system should go out of master RF
initialization mode).
Factory settings function:
Use this function to erase all configurations and download the factory settings.
In 'Run mode', press in the same time during 5 seconds the 2 keys (◄) and (►). Then the product has been
resetted.
10.

SYSTEM CONFIGURATION

Antenna
Relay pump is activated when there is
one zone activated at least.
(If BT-M6Z02 RF is master, relay pump
is activated if there is one zone
ON
activated
network.
If BT-M6Z02 RF is slave, relay pump is
activated if there one zone of slave
network activated at least.)
OFF
Relay pump is not used
If BT-M6Z02 RF is slave, relay pump is activated on both the master and the slave if there is one zone of slave
network at least activated.
your BT-M6Z02 RF will operate alone with its local network.
Switch 1
at
least
on
the
global
ON
OFF
ON
OFF
Switch 2
Switch 3
Outputs are
There is a pump
normally opened
Outputs are
There is no pump
normally closed
9
No pump exercise
Zone outputs NC
Deported pump
Pump exercise activated
Zone outputs NO
Local pump
Switch 4
Not used
exercise.
Not used
exercise